MICROCRE / OPTICAL METROLOGY400-812-7833  ·  SHANGHAI
研润 WHW
MICROCREPRECISION IN EVERY ANGLE
Home / Automotive & New Energy
APPLICATION GUIDE

Automotive & New Energy

Inspection fixtures, assembly tooling, machining equipment and electric-drive test stands.

Methods

Procedure

  1. Define inspection targets
  2. Check references
  3. Measure key features
  4. Adjust
  5. Verify and record

The actual inspection plan must reflect drawing tolerances and production conditions.

MEASUREMENT SCENARIOS

Typical measurement scenarios in this industry

Each scenario gives the object, tolerance range and method, ready to take to the selector.

Open in the atlas ↗
STEP BY STEP

Understand the measurement step by step

  1. 01

    Define inspection targets

  2. 02

    Check references

  3. 03

    Measure key features

  4. 04

    Adjust

  5. 05

    Verify and record

Principle schematic · not to scale
1 / 4
  1. Identify fixture datums · Use the fixture drawing to identify datum direction A and compared direction B, specifying suitable reference mirrors, angle references or other direction-transfer devices.
  2. Check references · Check reference calibration and mounting. Maintain specified support, clamping and temperature conditions, documenting the direction definitions as well as readings.
  3. Measure angular error · Repeat the angle comparison, apply known reference corrections and report the signed deviation from 90°.
  4. Interpret length effect · Convert the direction error to an illustrative displacement over a specified length. For surface-perpendicularity acceptance, add surface sampling, form error and complete datum rules.

Teaching animation: follow the stations and reference directions. Do not read dimensions or angles from the schematic.

WORKED EXAMPLE

Automotive fixture: converting a right-angle direction error to a length effect

Teaching example with assumed data, not a customer project, instrument accuracy claim or acceptance result.

Example task

Teaching demonstration, not a real customer project. Two reference directions on a powertrain assembly fixture illustrate how a departure from 90° produces a directional offset over 400 mm. This is not a complete surface-perpendicularity inspection.

Setup and preparation

  • Use the fixture drawing to identify datum direction A and compared direction B, specifying suitable reference mirrors, angle references or other direction-transfer devices.

  • Check reference calibration and mounting. Maintain specified support, clamping and temperature conditions, documenting the direction definitions as well as readings.

  • Repeat the angle comparison, apply known reference corrections and report the signed deviation from 90°.

  • Convert the direction error to an illustrative displacement over a specified length. For surface-perpendicularity acceptance, add surface sampling, form error and complete datum rules.

Example data and records

  • Illustrative included angle: 90°+3.00″.

  • Length of interest L=400 mm; only the directional angular component is calculated.

  • No drawing tolerance is specified, so no pass/fail decision is made.

Calculation steps

δ=3.00″=3π/648000 rad; e=L tanδ=400×1000×tan(3π/648000)≈5.817764 μm.

Interpretation

The angular component produces an illustrative offset of approximately 5.817764 μm over 400 mm. It explains assembly-direction sensitivity, not complete fixture or part acceptance.

Verification and pitfalls

  • Check the right-angle reference or direction-transfer error rather than attributing it entirely to the fixture.

  • Clamped and unclamped states can differ; verify the state required by the drawing.

  • Actual surface perpendicularity also depends on form, sampling coverage and datum construction.