Principle
A calibrated right-angle reference connects two directions while retaining orientation and form information.
Preparation
Specify the datum, measurement length, plane and feature type. Use a calibrated optical square or an appropriate right-angle reference.
Workflow diagram
Procedure
- Identify whether the requirement concerns an angular relationship or a complete datum-constrained tolerance zone.
- Measure the first axis or datum feature, retaining its direction and form data.
- Transfer the direction through a calibrated right-angle reference and measure the second feature.
- Evaluate axis squareness as a direction difference; evaluate feature perpendicularity from all relevant points under the specified datum constraint.
- Repeat after reversal or re-setup and record reference corrections, measured length and results.
Calculation
Axis squareness deviation δ=α−90°. For a small directional error, e≈Lδrad; surface perpendicularity additionally requires datum-constrained point evaluation.
Illustrative example
Illustration: 2″ over 500 mm corresponds to about 4.85 μm of directional tilt, excluding surface form.
Limitations
- A 90-degree relationship between fitted lines does not prove full-surface perpendicularity.
- The right-angle reference error must be corrected or included in uncertainty.
- Do not remove all directional information before comparing axes.
Reporting
Retain raw data, datum definition, temperature, repeatability, algorithm and uncertainty. Illustrations are not test results.