MICROCRE / OPTICAL METROLOGY400-812-7833  ·  SHANGHAI
研润 WHW
MICROCREPRECISION IN EVERY ANGLE
Home / Straightness
MEASUREMENT METHOD

Straightness

Assess the form of a selected line on a guideway, moving stage or reference surface in the specified measurement plane.

Principle

Mirror rotation changes the return-image position. Calibrated angular readings and the effective base span support height reconstruction.

Preparation

Define the line, travel, evaluation reference and tolerance. Clean the supports and verify reflector span, step spacing, calibration and thermal stability.

Workflow diagram

01Mark equally spaced stations and record the actual spa02Align the autocollimator and verify the return beam ov03Move the base in sequence and record stable angular re04Convert angular readings to height increments using th05Repeat in reverse and report the profile

Procedure

  1. Mark equally spaced stations and record the actual span between the reflector base contacts.
  2. Align the autocollimator and verify the return beam over the full travel.
  3. Move the base in sequence and record stable angular readings without changing its orientation.
  4. Convert angular readings to height increments using the actual geometry; accumulate and evaluate using the agreed reference method.
  5. Repeat in reverse and report the profile, repeatability, environment and uncertainty information.

Calculation

θrad=θ″π/648000; Δh=L tan(θrad). For L in mm, multiply by 1000 for μm. Accumulate interval increments, then apply the specified evaluation reference.

Illustrative example

Schematic · not measured data
Schematic: the reflector follows equal-step stations; arrows indicate sequence, not measured data.

Illustration: L=100 mm and θ=1″ give about 0.4848 μm over one interval, not the straightness of the entire guideway.

Limitations

  • An autocollimator measures reflector angle, not surface height directly.
  • A mismatch between sampling steps and base span can invalidate reconstruction.
  • One measured line does not establish the flatness of an entire surface.

Reporting

Retain raw data, datum definition, temperature, repeatability, algorithm and uncertainty. Illustrations are not test results.

Method reference ↗ Method reference ↗ 
STEP BY STEP

Understand the measurement step by step

Principle schematic · not to scale
1 / 4
  1. Define the line · Define the measurement direction, a 100 mm station interval and a 100 mm support span; mark five height nodes and four angular intervals.
  2. Read angles · Set the initial relative height to zero and simulate four stable interval readings, keeping the base orientation unchanged.
  3. Integrate heights · Convert each interval with Δh=L·tanθ and accumulate signed increments; never reset each station independently.
  4. Fit and verify · Fit a least-squares line to the five heights and plot the residuals; plan a reverse run to examine contact effects and drift.

Teaching animation: follow the stations and reference directions. Do not read dimensions or angles from the schematic.

WORKED EXAMPLE

Integrating angular readings along a guideway

Teaching example with assumed data, not a customer project, instrument accuracy claim or acceptance result.

Example task

Teaching demonstration, not a real customer project: a simplified base with support span equal to station spacing shows how angular readings become a profile. These values are not instrument performance claims.

Setup and preparation

  • Define the measurement direction, a 100 mm station interval and a 100 mm support span; mark five height nodes and four angular intervals.

  • Set the initial relative height to zero and simulate four stable interval readings, keeping the base orientation unchanged.

  • Convert each interval with Δh=L·tanθ and accumulate signed increments; never reset each station independently.

  • Fit a least-squares line to the five heights and plot the residuals; plan a reverse run to examine contact effects and drift.

Example data and records

  • Station interval and support span: 100 mm.

  • Interval angles: [+1, 0, −1, 0] arcsec; nodes at 0, 100, 200, 300 and 400 mm.

  • Accumulated heights: [0, 0.484814, 0.484814, 0, 0] μm.

Calculation steps

θrad=θarcsec·π/648000; 100·tan(1 arcsec)·1000=0.484814 μm. Least-squares residuals are [−0.290888, +0.242407, +0.290888, −0.145444, −0.096963] μm; their peak-to-valley value is 0.581776 μm.

Interpretation

The worked least-squares residual range is about 0.5818 μm. It describes this sampled line and reference model, not whole-surface flatness or minimum-zone straightness.

Verification and pitfalls

  • Verify which interval each angle represents and whether the actual base geometry fits the model.

  • Preserve raw angles, signs and the evaluation reference as well as the final range.

  • A reverse run and uncertainty are absent from this arithmetic, so it is not an acceptance result.