Bed guideway inspection plan for a roll grinder
For straightness and twist of the extra-long guideways of a roll grinder bed (12000 mm, example/teaching data). Multi-segment spliced measurement is used; the first station of each segment is re-read to monitor drift, with the temperature field and instrument relocation error tightly controlled.
Instruments
- Dual-axis long-focus photoelectric autocollimator (0.1″ class)
- 200 mm reflector base and a bridge spanning both guideways (example)
- Multi-point bed thermometers
- Segment markers and drift re-read log
Procedure
- Confirm the 12000 mm bed (example), segmentation (6×2000 mm), 200 mm span and endpoint-line datum agreement.
- Level the bed, let it settle and record the multi-point temperature field.
- Measure segment by segment with 3 overlapping intervals between neighbours; read roll at each station with the bridge simultaneously.
- At the end of each segment re-read its first station for drift; if the drift exceeds the criterion (1″, example), re-measure that segment.
- Register the overlaps by least squares into the full profile and evaluate straightness and twist via Δh=L·tanθ integration.
- Reverse-repeat the full length once and compare splice-zone consistency.
- Deliver the full profile, twist curve, temperature records and raw segment data.
Calculation
Δh=L·tanθ; with L=200 mm, 1″≈0.970 μm (example/teaching data). Splicing minimises squared height differences in the overlaps; twist = roll angle × bridge span B; thermal drift is corrected linearly from each segment's re-read difference.
Reporting
- Temperature field log complete
- Drift re-read passed for every segment
- Overlap at least 3 intervals
Limitations
Does not cover hot-state grinding deformation or bed deformation under roll weight; the measurement cycle is long, so the report must state the environment window and the temperature correction method.
Understand the measurement step by step
- 01
Confirm the 12000 mm bed (example), segmentation (6×2000 mm), 200 mm span and endpoint-line datum agreement.
- 02
Level the bed, let it settle and record the multi-point temperature field.
- 03
Measure segment by segment with 3 overlapping intervals between neighbours; read roll at each station with the bridge simultaneously.
- 04
At the end of each segment re-read its first station for drift; if the drift exceeds the criterion (1″, example), re-measure that segment.
- 05
Register the overlaps by least squares into the full profile and evaluate straightness and twist via Δh=L·tanθ integration.
- 06
Reverse-repeat the full length once and compare splice-zone consistency.
- 07
Deliver the full profile, twist curve, temperature records and raw segment data.
- Oil temperature · Wait for hydrostatic oil temperature to settle.
- Head station · Autocollimator fixed at the bed head.
- Guide segments · The 200 mm bridge walks the V-guide.
- Log readings · Pitch values recorded per segment.
- Straightness · Cumulative conversion gives straightness.
Teaching animation: follow the stations and reference directions. Do not read dimensions or angles from the schematic.
Roll Grinder Bed Guide Inspection · Tutorial Case
Teaching example with assumed data, not a customer project, instrument accuracy claim or acceptance result.
Example task
Teaching demonstration, not a real customer project: first three segments of a long-travel straightness survey on a roll grinder bed guide; data are instructional settings.
Setup and preparation
Clean the bed guide and confirm hydrostatic oil temperature is stable
Fix the autocollimator on a stand at the head of the bed
Survey with a 200 mm bridge along the V-guide step by step
Record the pitch reading per segment
Cumulate three segments for straightness results
Example data and records
Bridge span L=200 mm; segment 1 autocollimator reading θ₁=+1″
Segment 2 autocollimator reading θ₂=+0.5″
Segment 3 autocollimator reading θ₃=-1.5″
Calculation steps
Height conversion: Δh = L·tan(θ·π/648000)×1000 (μm). Segment 1: 200×tan(+1″)=+0.97 μm; Segment 2: 200×tan(+0.5″)=+0.48 μm; Segment 3: 200×tan(-1.5″)=-1.45 μm. Cumulative heights: 0→+0.97→+1.45→+0.00 μm; peak-to-valley PV=+1.45−(+0.00)=+1.45 μm.
Interpretation
Tutorial result PV≈1.45 μm, demonstrating long-travel guide inspection on the grinder bed.
Verification and pitfalls
Measure only after hydrostatic oil temperature stabilises
Bridge contacts the guide without gaps
Check instrument zero before surveying