MICROCRE / OPTICAL METROLOGY400-812-7833  ·  SHANGHAI
研润 WHW
MICROCREPRECISION IN EVERY ANGLE
Home / Measuring Spindle Tilt Error Motion
MEASUREMENT METHOD

Measuring Spindle Tilt Error Motion

Measure the tilt error motion of a spindle or axis of rotation, the variation of the instantaneous axis inclination about the mean axis with angle. Tilt error affects face machining and angular indexing accuracy. It suits spindle acceptance, accuracy diagnosis and error-compensation modelling.

Principle

A plane mirror is attached to the spindle face, roughly normal to the axis, while a two-axis autocollimator reads its tilt in two orthogonal directions. During rotation the tilt sequence contains a once-per-revolution component corresponding to spindle-axis tilt plus the contribution of mirror mounting eccentricity. The distinction matters: pure translation of a plane mirror does not change the reading, only tilt does; mounting eccentricity traces a cone of the mirror normal, also appearing as a once-per-revolution harmonic. The classical remedy is measuring over full turns in both directions or at two positions to separate eccentricity from genuine tilt error motion.

Preparation

Clean the spindle face and prepare a rigid mirror mount with minimal radial and axial runout after installation. Set the autocollimator at a suitable distance with return light throughout the rotation. Choose sampling: continuous or stepwise at discrete angles. Record speed, temperature and support conditions such as bearing preload changes.

Workflow diagram

01Mount the mirror02Set two-axis autocollimator03Sample over rotation04Harmonic separation05Report error curves06Report indices and conditions

Procedure

  1. Mount the mirror on the spindle face, aligning its initial tilt near mid-range of the autocollimator.
  2. Aim at the mirror centre and confirm both readings stay in range through the full rotation.
  3. Rotate the spindle at the set speed or step and record angle plus both tilt readings synchronously.
  4. Acquire at least one full revolution, usually averaging several to suppress random noise.
  5. Perform harmonic analysis on both sequences: extract once- and higher-order harmonics and use two-position or two-direction data to separate mounting eccentricity from true tilt error.
  6. Report polar curves of tilt error versus angle with peak indices and measurement conditions.

Calculation

The two readings θx(φ) and θy(φ) combine as θ(φ)=√(θx²+θy²). First-harmonic fits θx=a1·cosφ+b1·sinφ+c1 (likewise θy) describe the composite of spindle tilt and mirror eccentricity; with two-position measurements half the difference of the two first harmonics yields the pure tilt component (classical treatment, derived per layout). Peak indices take the maximum of θ(φ) or the maximum deviation from the mean axis.

Illustrative example

Schematic · not measured data
Schematic: tilt locus of the spindle-face mirror versus angle; values illustrative.

Teaching data, not measured: suppose mirror eccentricity contributes a first harmonic of 2″ and true spindle tilt 0.8″. A single-position measurement reads their vector composite (a demonstration magnitude of about 2.6″); two orthogonal positions separate the true tilt of about 0.8″. The numbers only illustrate the separation.

Limitations

  • Attributing the whole first harmonic to spindle tilt while ignoring mirror eccentricity.
  • Incomplete or uneven sampling over the revolution distorts the harmonic analysis.
  • A compliant mirror mount mixes structural vibration into the readings.

Reporting

Retain raw data, datum definition, temperature, repeatability, algorithm and uncertainty. Illustrations are not test results.

Method reference ↗ Method reference ↗ 
STEP BY STEP

Understand the measurement step by step

Principle schematic · not to scale
1 / 5
  1. The mirror on the spindle nose with the two-axis autocollimator on the table, X and Y live.
  2. The spindle steps through 0°, 90°, 180° and 270° and the readings fill the table.
  3. The readings are plotted in polar form and the eccentricity harmonic is obvious.
  4. The mirror is reversed 180° and the harmonic flips while the mean stays put.
  5. After averaging, the harmonic cancels and the tilt 3.09″ plus 4.49 μm over 300 mm appear.

Teaching animation: follow the stations and reference directions. Do not read dimensions or angles from the schematic.

WORKED EXAMPLE

Spindle tilt error of a machining centre (two-position eccentricity removal)

Teaching example with assumed data, not a customer project, instrument accuracy claim or acceptance result.

Example task

A vertical machining centre is checked after assembly for the tilt of its spindle axis relative to Z. A plane mirror is mounted on the spindle nose and a two-axis autocollimator reads the tilt in X and Y. The spindle stops at four 90° positions for readings, then the mirror is reversed 180° on the spindle and the four positions are repeated so that mounting eccentricity can be separated from true tilt.

Setup and preparation

  • Mount a φ80 mm plane mirror on the spindle nose with a fixture and align its normal to the axis of rotation within 10′.

  • Place the two-axis autocollimator on the table, aim at the mirror centre and confirm both channels stay within ±300″ over a full revolution.

  • Run the spindle at 60 r/min and stop at each 90° position, waiting 5 s before recording X and Y.

  • After the four positions, reverse the mirror and fixture 180° on the spindle and repeat the same four positions.

  • Average each set for the true tilt and take the once-per-revolution amplitude as mounting eccentricity; the harmonic changes sign between sets and cancels.

  • Record 20.5 °C and keep spindle running time under 10 min to limit thermal growth.

Example data and records

  • Spindle 0°: X +3.20″, Y -1.40″

  • Spindle 90°: X +2.85″, Y +0.55″

  • Spindle 180°: X +3.35″, Y +1.45″

  • Spindle 270°: X +2.95″, Y -0.50″

  • Mirror reversed 180° on the spindle, 0°: X +3.15″, Y +1.35″

  • Reversed, 90°: X +2.90″, Y -0.60″

  • Reversed, 180°: X +3.30″, Y -1.50″

  • Reversed, 270°: X +3.00″, Y +0.45″

  • Spindle at 60 r/min, stopped 5 s at each 90° step; 20.5 °C

Calculation steps

First set means: X +3.09″, Y +0.03″; first-harmonic amplitudes X 0.09″, Y 1.52″. Second set (mirror reversed): means X +3.09″, Y -0.07″; harmonics X 0.09″, Y 1.52″. Reversing the mirror flips the sign of the eccentricity harmonic while leaving the mean tilt unchanged, so the average gives the true tilt X +3.09″, Y -0.02″, i.e. 3.09″ combined; Both sets show the same harmonic magnitudes (X 0.09″, Y 1.52″) with opposite phase, so averaging cancels them, proving that the 1.52″ comes from mirror eccentricity rather than spindle tilt. A tilt of 3.09″ over 300 mm is 300×tan(3.09″)×1000=4.49 μm, or 0.015 μm/mm.

Interpretation

Spindle tilt 3.09″, i.e. 4.49 μm over 300 mm (0.015 mm/300 mm). This passes the 0.02 mm/300 mm squareness tolerance with 15.5 μm margin.

Verification and pitfalls

  • A two-position measurement is mandatory: the 1.52″ Y harmonic of a single set comes from mirror mounting eccentricity and would overstate the tilt by an order of magnitude.

  • The two means must agree (X +3.09″ against +3.09″); a difference above 0.1″ means the reversal was not seated properly.

  • Keep the initial angle between mirror normal and axis under 10′, otherwise the autocollimator shows a cosine error at large tilt.

  • Read with the spindle stopped and thermally settled; after 30 min of running, thermal growth drifts the tilt by 0.3″.

  • Repeat each position twice and require agreement within 0.1″; otherwise verify that the spindle servo is really locked.