MICROCRE / OPTICAL METROLOGY400-812-7833  ·  SHANGHAI
研润 WHW
MICROCREPRECISION IN EVERY ANGLE
Home / MC030-WF100-10800 · Wide-field dual-axis electronic autocollimator maximum measuring distance 2m
PRODUCT TECHNICAL SHEET

MC030-WF100-10800 · Wide-field dual-axis electronic autocollimator maximum measuring distance 2m

Wide-field electronic autocollimators

MC030-WF100-10800
MC030-WF100-10800

Wide-field dual-axis electronic autocollimator maximum measuring distance 2m

Select using tolerance, distance, references and environmental conditions.

PDF for reading, editable Word; generated from the same source data.

Product overview

The wide-field electronic autocollimator series is intended for laboratory applications requiring a large angular measuring range. It supports angular measurement of large equipment and complex structures in scientific research and industrial development.

Applications

Machine tools: guideway straightness, parallelism and perpendicularity, and flatness of large surface plates. Optics: assembly, alignment and prism-angle measurement. Metrology and research: verification and calibration of measuring instruments and tools, precision angle measurement, dynamic monitoring of angular position, and angular or straightness-error measurement of moving products. Marble inspection: straightness, parallelism, perpendicularity and flatness. Encoders: angular-encoder positioning accuracy and repeatability.

Specifications

Objective focal length100mm
Clear aperture38mm
Maximum measuring distance2m
Field of view (X, Y)3*3°
Resolution0.1″, 0.01″, 0.001″, 0.0001″ adjustable (arc sec. arcseconds )
Indication accuracy±1000″≤ ±2″; Full range≤ ±5″
Repeatability≤ 0.5″
Centre wavelength625nm
Measurement frequency response≤ 30HZ(Hz TYP.)
Light source typeSemiconductor LED light source
CommunicationUSB3.0
Third-party communication interfaceRS-232
Display methodSoftware display on a standard PC
Power supply5V1A
Instrument dimensions (L * W * H)157*115*105mm
Main unit weight1.81kg

Original source ↗ · 2026-11-14

Resolution is not accuracy. Preserve range conditions and confirm missing data with the engineering team.

MOTION DIAGRAM

How it works, animated

Four steps: where the light comes from, where it returns, how the reading appears.

Source / reticleObjective fPlane mirrorDetector: image shift → angle2θθ ≈ x / 2fSchematic · not to scale · not measured data
1 / 4
  1. Optical path: source collimated by the objective
  2. The mirror returns the beam along its own path
  3. The image point moves; the detector reads the shift
  4. Convert with θ = x/2f

The animation shows the optical path and how a reading arises. It does not represent the resolution, range or accuracy of this model.

Where this instrument is used

Product and measurement standards

References to check for selection, specifications and methods. Listing does not certify this model or prove testing to a standard; confirm the edition and applicable clauses in the technical agreement.

Product standard reference

JB/T 8232-2024 · Autocollimators

Product-standard candidate; confirm model applicability and inspection records. No conformity claim.

Official directory ↗
Application method reference

GB/T 17421.1-2023 · Machine tool testing — No-load or quasi-static geometry

Application, geometrical specification or evaluation reference; not a claim of instrument conformity.

Official directory ↗
Application method reference

GB/T 1958-2017 · GPS — Geometrical tolerance inspection and verification

Application, geometrical specification or evaluation reference; not a claim of instrument conformity.

Official directory ↗
Application method reference

GB/T 18779.1-2022 · GPS inspection — Conformity decision rules

Application, geometrical specification or evaluation reference; not a claim of instrument conformity.

Official directory ↗
Application method reference

ISO 230-1:2012 · Machine tools — Geometric accuracy under no-load or quasi-static conditions

Application, geometrical specification or evaluation reference; not a claim of instrument conformity.

Official directory ↗
Application method reference

ISO/TR 230-11:2018 · Measuring instruments for machine tool geometry tests

Instrument-selection technical report, not a manufacturing or product-certification standard.

Official directory ↗
Application method reference

ISO 12780-1:2011 · Straightness — Vocabulary and parameters

Application, geometrical specification or evaluation reference; not a claim of instrument conformity.

Official directory ↗
Application method reference

ISO 12781-1:2011 · Flatness — Vocabulary and parameters

Application, geometrical specification or evaluation reference; not a claim of instrument conformity.

Official directory ↗
Application method reference

ISO 14253-1:2017 · GPS — Conformity decision rules

Application, geometrical specification or evaluation reference; not a claim of instrument conformity.

Official directory ↗

GB/ISO entries mainly reference application methods. JB/T 8232-2024 is a product-standard candidate; model applicability and inspection records require confirmation. No conformity claim is made.