JB/T 8232-2024 · Autocollimators
Product-standard candidate; confirm model applicability and inspection records. No conformity claim.
Official directory ↗Zhongji high-speed dynamic autocollimators

Select using tolerance, distance, references and environmental conditions.
PDF for reading, editable Word; generated from the same source data.
The MC030-ZJHS high-speed electronic autocollimator series combines a precision imaging system with a high-speed photoelectric detector. The source describes sampling rates of 100HZ, 200HZ, 500HZ or higher across the series. Applications include dynamic monitoring of small angles and online inspection of geometric accuracy. The individual model specifications determine the applicable sampling rate.
Machine tools: guideway straightness, parallelism and perpendicularity, and flatness of large surface plates. Optics: assembly, alignment and prism-angle measurement. Metrology and research: verification and calibration of measuring instruments and tools, precision angle measurement, dynamic monitoring of angular position, and angular or straightness-error measurement of moving products. Marble inspection: straightness, parallelism, perpendicularity and flatness. Encoders: angular-encoder positioning accuracy and repeatability.
| Objective focal length | 300mm |
| Clear aperture | 48mm |
| Maximum measuring distance | 30m |
| Field of view | 2100*1600″ |
| Resolution | 0.1″ (adjustable) |
| Indication accuracy | ±600″± 0.5″ |
| Light source type | Imported high-power LED |
| Communication | USB2.0 |
| Signal acquisition | High-precision photoelectric sensor |
| Display method | Software display on a standard PC |
| Instrument dimensions (L*W*H) | 390*135*125mm |
| Power supply | Integrated power supply |
| Sampling rate | up to 200HZ |
Original source ↗ · 2026-11-14
Resolution is not accuracy. Preserve range conditions and confirm missing data with the engineering team.
Four steps: where the light comes from, where it returns, how the reading appears.
The animation shows the optical path and how a reading arises. It does not represent the resolution, range or accuracy of this model.
Long-duration tests shift the load line as structure and actuators heat. A fixed mirror sampled continuously converts angle drift into eccentricity with a threshold alarm.
Thermal Drift & Stability↗Sample one target for 10 min and read peak-to-peak angle noise and spectrum to judge foundation, isolators and air supply.
Repeatability & Re-setup Verification↗A line takt allows 10 s per measurement. Run 30 repeats first and confirm 2σ is below one tenth of the tolerance band before release.
Repeatability & Re-setup Verification↗References to check for selection, specifications and methods. Listing does not certify this model or prove testing to a standard; confirm the edition and applicable clauses in the technical agreement.
Product-standard candidate; confirm model applicability and inspection records. No conformity claim.
Official directory ↗Application, geometrical specification or evaluation reference; not a claim of instrument conformity.
Official directory ↗Application, geometrical specification or evaluation reference; not a claim of instrument conformity.
Official directory ↗Instrument-selection technical report, not a manufacturing or product-certification standard.
Official directory ↗Application, geometrical specification or evaluation reference; not a claim of instrument conformity.
Official directory ↗Quasi-static GB/ISO methods do not establish bandwidth or dynamic accuracy. Confirm separate dynamic tests and the applicability of JB/T 8232-2024; no conformity claim is made.