Application atlas
Eighteen industries broken into concrete measurement scenarios, each stating the object, typical tolerance, method and recommended series — filterable by industry and stage.
150 scenarios · open a card for the full industry note
Column-to-crossbeam squareness
Vertical machining centre column to table, or gantry column to crossbeam, 1–4 m travel. A pentaprism folds the beam through 90° so both axes separate pitch from yaw.
Perpendicularity & SquarenessMachine-tool autocollimator series ↗Guideway straightness, horizontal and vertical plane
Bed or carriage guideways, 0.5–6 m long, typically 5–10 μm/m. Read angles at 200–500 mm spans and accumulate to a profile evaluated by minimum zone.
StraightnessMachine-tool autocollimator series ↗Ram travel squareness to table
Travel 500–800 mm, 0.01–0.02 mm; a pentaprism reaches hidden directions.
Perpendicularity & SquarenessMachine-tool autocollimator series ↗Geometry check after machine rebuild
After scraping, rail replacement or column realignment, re-measure the GB/T items in order: straightness and squareness first, then parallelism and coaxially.
Guideway Adjustment & VerificationLaser autocollimators ↗C-axis indexing accuracy of CNC rotary tables
Indexing error of 5-axis rotary tables by polygon and autocollimator comparison; typical acceptance ±5″ to ±15″, with compensation table output.
Rotary Positioning & ReversalGoniometers ↗NC rotary table indexing error
Four- and five-axis tables indexed every 15° or 30°. A polygon serves as the angle reference; measure in both directions to separate backlash.
Rotary Positioning & ReversalGoniometers ↗Spindle axis parallelism to guideways
Parallelism of a boring/mill spindle axis to guideway motion, measured in two planes; typically 0.01–0.03 mm/300 mm.
ParallelismMachine-tool autocollimator series ↗Table and mounting-face flatness
Tables 300–1200 mm and both sides of T-slots. A 5×5 to 9×9 grid measured by the pitch method is integrated; typical requirement 10–20 μm.
FlatnessMetrology autocollimator series ↗Table rail twist
Span 300–500 mm, lateral tilt ≤ 0.02 mm/m; keep the bridge span fixed.
Guideway twist and rail height differenceMachine-tool autocollimator series ↗Tailstock to spindle coaxiality
Two sections give offset and tilt; typically ≤ 0.02 mm with the quill clamped.
Coaxiality and runout by two sectionsMachine-tool autocollimator series ↗Large assembly platform flatness and equal height
Multi-point supported platforms 2–6 m need both flatness and equal support height: measure flatness first, then combine gauge blocks with the autocollimator for point heights.
FlatnessMetrology autocollimator series ↗Load-axis drift monitoring on fatigue rigs
Long-duration tests shift the load line as structure and actuators heat. A fixed mirror sampled continuously converts angle drift into eccentricity with a threshold alarm.
Thermal Drift & StabilityZhongji high-speed dynamic autocollimators ↗Assembly jig datum faces and locator coaxially
Wing-box and fuselage jigs spanning 3–15 m. Each locator carries a mirror; one optical axis is established from the jig datum and pitch/yaw read point by point to hold 0.05 mm assembly deviation.
Optical AlignmentWide-field electronic autocollimators ↗Long guide rails: straightness and twist
Moving structures on final assembly lines, 8–30 m. Long paths demand attention to air movement and floor vibration; keep span and orientation fixed and log twist separately.
StraightnessLaser autocollimators ↗Optical payload mounting angle and line of sight
After a camera, star tracker or laser terminal is mounted, measure the angle between its mounting normal and the spacecraft datum, usually to arcseconds, after thermal stabilisation.
Small Angles & Indexing ErrorMetrology autocollimator series ↗Perpendicularity of airborne antenna bases
Perpendicularity of radar/antenna base faces to airframe datums drives pointing accuracy; check on site with autocollimator and steering mirror.
Perpendicularity & SquarenessZhongji automatic measurement series ↗Composite panel contour and flatness
Panels 2–6 m, contour ±0.5 mm; photogrammetry or structured light.
FlatnessGeneral-purpose electronic autocollimators ↗Wing fixture datum transfer
Multi-station transfer, closure ≤ 0.1 mm; gradients and foundation dominate.
Datum Transfer & Closure ChecksGeneral-purpose electronic autocollimators ↗Coplanar alignment of wing jig locators
Wing jig locators must be coplanar or collinear over metres; align point by point with autocollimator and targets at 0.05–0.1 mm level.
Optical AlignmentZhongji fully automatic autocollimators ↗Autocollimation demonstration
A beamsplitter and flat mirror show parallel out and focus-plane return; students turn the drum and read arcseconds to build intuition.
Small Angles & Indexing ErrorGeneral-purpose electronic autocollimators ↗Error sources and uncertainty project
Students design a measurement, list at least six error sources, combine them, and explain why their result differs from a classmate's.
Measurement Uncertainty BudgetGeneral-purpose electronic autocollimators ↗Grid-method flatness exercise
A 5×5 grid on a 300×300 mm plate: groups measure, swap data and evaluate separately to compare methods.
FlatnessGeneral-purpose electronic autocollimators ↗Optical assembly and alignment practicum
From seating a lens to aligning the group, accept at element, assembly and system level so students locate error before adjusting.
Optical AlignmentWide-field electronic autocollimators ↗Repeatability and reproducibility study
Three operators, ten repeats each: compare within and between groups to see that a good instrument is not a good system.
Repeatability & Re-setup VerificationGeneral-purpose electronic autocollimators ↗Pitch-method straightness exercise
Eleven points at 100 mm on a 1 m rail: hand-accumulate, fit least squares, then verify in software to see angles integrate into a profile.
StraightnessGeneral-purpose electronic autocollimators ↗Teaching lab on uncertainty evaluation
Using prism dihedral measurement as the vehicle, train repeatability statistics, component combination and k=2 expanded uncertainty reporting in 2 teaching hours.
Measurement Uncertainty BudgetGeneral-purpose electronic autocollimators ↗Optical table levelling and post-isolation stability
Five points (four corners plus centre), level to within 10″, then log for 30 min with air isolation on to confirm no slow tilt.
Stage Pitch & YawMetrology autocollimator series ↗Substrate figure change after coating
Coating stress bows the substrate. Compare the reflected angle at the same point before and after coating to decide whether tooling compensation is needed.
Small Angles & Indexing ErrorZhongji automatic measurement series ↗Interferometer path alignment and reference flat attitude
Reference flat attitude relative to the stage affects fringe reading; monitor alignment with an autocollimator down to arc-seconds.
Optical AlignmentGeneral-purpose electronic autocollimators ↗Lens decentre and group coaxially
Rotate the group and watch the image wobble; the radius of the traced circle gives decentre. Judge element by element so error does not accumulate in the assembly.
Optical AlignmentWide-field electronic autocollimators ↗Mirror assembly optical axis alignment
After the mirror sits in its cell, watch the returned image and adjust pitch and yaw screws into 5–30″; lock and re-check drift.
Optical AlignmentWide-field electronic autocollimators ↗Prism and wedge angle verification
90° prisms and small wedge angles. Use a polygon or angle gauge, measure face by face, and correct for incidence angle and refractive index.
Prism & Polygon Angle ComparisonGoniometers ↗Lens centring and axis consistency
Groups 5–200 mm, centring 5–20 μm; rotation gives image jump.
Optical AlignmentGeneral-purpose electronic autocollimators ↗Prism and wedge angle
10°–90°, typically 2–10″; autocollimator with a rotary table and closure check.
Prism & Polygon Angle ComparisonGoniometers ↗Chuck and wafer-stage flatness
150–300 mm diameter, often 1–3 μm. For small high-precision areas an autocollimator with a short base avoids an interferometer's field limit.
FlatnessMetrology autocollimator series ↗Dual-drive gantry synchronisation and orthogonality
Unequal drives yaw the beam. Two instruments, or one multi-channel unit, read both ends and give yaw and synchronisation error directly.
Perpendicularity & SquarenessZhongji automatic measurement series ↗Precision XY stage pitch and yaw
Strokes of 50–300 mm, often 1–5″. Sample every 10–20 mm across the travel and watch periodic components and reversal jumps.
Stage Pitch & YawZhongji fully automatic autocollimators ↗Viewport alignment into a vacuum chamber
Measuring through a window adds refraction and figure error. Correct for incidence angle and cross-check against an external reference mirror.
Optical AlignmentWide-field electronic autocollimators ↗Vibration and repeatability check after installation
Sample one target for 10 min and read peak-to-peak angle noise and spectrum to judge foundation, isolators and air supply.
Repeatability & Re-setup VerificationZhongji high-speed dynamic autocollimators ↗Two-plane straightness acceptance of stage guideways
Granite stage guideways with a few hundred millimetres of travel at 0.5 μm level; read at 50 mm spans and evaluate both planes by minimum zone.
StraightnessMetrology autocollimator series ↗Electrostatic chuck flatness
Chucks Ø 200–300 mm, 1–2 μm; measure at working temperature and clamping.
FlatnessGeneral-purpose electronic autocollimators ↗Lift pin synchronisation and table level
Asynchronous pins slip the wafer; check with displacement sensors or multi-point level.
Levelling and datum establishmentGeneral-purpose electronic autocollimators ↗Battery tray flatness and sealing face
Trays of 1–2 m need 0.2–0.5 mm flatness along the seal groove. Sample along the sealing path, not only on a central grid.
FlatnessMetrology autocollimator series ↗Body-in-white fixture datum consistency
Across stations on the main line, one optical axis ties datum holes and locating faces together to check whether station-to-station deviation exceeds the 0.1 mm window.
Optical AlignmentWide-field electronic autocollimators ↗End-of-line station cycle time and repeatability
A line takt allows 10 s per measurement. Run 30 repeats first and confirm 2σ is below one tenth of the tolerance band before release.
Repeatability & Re-setup VerificationZhongji high-speed dynamic autocollimators ↗Paint and weld robot base levelling
Base level directly affects TCP accuracy, typically within 0.2 mm/m; re-check parallelism to the track at the same time.
Small Angles & Indexing ErrorZhongji automatic measurement series ↗Cylinder block main-bore coaxially
For long bores, a centred mirror target in each bore gives centre offset, faster than a mandrel and directly referenced to the first bore.
ParallelismMachine-tool autocollimator series ↗Coplanarity of welding fixture datum faces
Coplanarity of BIW welding fixture datum faces drives body accuracy; check periodically by autocollimator grid method, typically 0.05–0.1 mm.
FlatnessMachine-tool autocollimator series ↗Very long guideway joint straightness
Over 20 m, joint steps 5–10 μm; staged datum transfer with closure.
StraightnessLaser autocollimators ↗Large slewing ring mounting face
2–5 m diameter, 0.1–0.2 mm; record free and preloaded states.
FlatnessGeneral-purpose electronic autocollimators ↗Large train shaft alignment
Motor, gearbox and main machine: cold alignment must allow for thermal growth. Two-section readings give the tilt, converted to coupling face offsets.
Optical AlignmentWide-field electronic autocollimators ↗Crane rail straightness and elevation difference
Overhead crane rails tens of metres long: straightness and rail-to-rail elevation difference affect travel; measure in segments with a long-range autocollimator.
StraightnessZhongji automatic measurement series ↗Foundation pads and bed levelling for large machines
Level on multiple pads to 0.1 mm/m first, re-check after grout cures, and record only after 24 h of thermal stability.
FlatnessMetrology autocollimator series ↗Double-column gantry synchronisation and beam twist
One instrument per column, or a multi-channel unit, sampled together. Beam twist shows as opposite pitch at the two ends and directly drives tool-height difference.
Stage Pitch & YawMulti-unit electronic autocollimator systems ↗Floor borer ram sag over extension
Ram extension of 1–3 m makes sag grow non-linearly. Read angles every 200–250 mm to obtain the deflection curve rather than an end-to-end chord.
StraightnessLaser autocollimators ↗Step and misalignment at welded rail joints
Rails joined from 12 m lengths past 40 m: step and kink at joints dominate. Sample densely on both sides and evaluate the kink separately.
StraightnessLaser autocollimators ↗Multi-point synchronous monitoring of ship lifts and large platforms
Multi-point hoist synchronisation of ship lifts: monitor tilt at all points simultaneously with a multi-head autocollimator; millimetre-level dynamic deviation maps to arc-second angles.
Stage Pitch & YawMulti-unit electronic autocollimator systems ↗CMM guideway and column geometry
Assess straightness per axis, squareness between axes and angular motion; acceptance follows the ISO 10360 or GB/T 16857 item set.
StraightnessMetrology autocollimator series ↗Angle gauge and polygon verification
Use the autocollimator as the readout with a rotary stage, comparing face by face at 20±0.5 °C, three repeats per face.
Small Angles & Indexing ErrorGoniometers ↗Cast-iron and granite plate flatness
Grid, diagonal or circular layouts. Grade 0 plates are often 3–8 μm; soak at least 12 h and keep away from sunlight and air outlets.
FlatnessMetrology autocollimator series ↗Square and box squareness
Reversal removes instrument bias: average the two readings of a forward and reversed setup so the autocollimator residual drops out.
Perpendicularity & SquarenessMetrology autocollimator series ↗Measurement uncertainty budget and report
List indication error, span, mirror angle, temperature and repeatability, combine by root-sum-square, and state method and datum in the report.
Measurement Uncertainty BudgetMetrology autocollimator series ↗Angle transfer
Transfer from polygon or angle blocks to working instruments, logging uncertainty at each step.
Small Angles & Indexing ErrorGoniometers ↗Surface plate calibration and lapping allowance
Grid measurement gives a lapping map instead of uniform removal.
FlatnessGeneral-purpose electronic autocollimators ↗Indication error comparison of autocollimators
Metrology labs check in-service autocollimators with angle gauges or small-angle generators; interim checks typically every 6–12 months.
Small Angles & Indexing ErrorMetrology autocollimator series ↗Indexing check of roundness tester spindles
Verify angular sampling intervals of roundness tester spindles with the polygon method so harmonic analysis rests on a correct angle base; annual check.
Rotary Positioning & ReversalGoniometers ↗AGV and mobile platform travel attitude
Fixed mirrors along the route give the yaw angle as the vehicle passes, verifying navigation repeatability and path adherence.
Stage Pitch & YawGeneral-purpose electronic autocollimators ↗Robot joint zero-position calibration aid
When restoring joint zero, verify the mechanical zero angle with a goniometer or autocollimator and target mirror; tolerance is usually within ±30″.
Small Angles & Indexing ErrorGoniometers ↗Robot base levelling and re-check
Six-axis robot base, typically 0.02–0.05 mm/m. Read pitch and roll together and re-check under load for the installation record.
Stage Pitch & YawGeneral-purpose electronic autocollimators ↗End-effector mounting attitude
The angle between flange and tooling datum sets grasp attitude. Attach a flat mirror to the flange and read the two-axis deviation directly.
Small Angles & Indexing ErrorZhongji automatic measurement series ↗Robot joint angular repeatability
Thirty round trips to one commanded pose give the angular spread. Compare with the rated repeatability to flag gearbox wear.
Repeatability & Re-setup VerificationZhongji high-speed dynamic autocollimators ↗Seventh-axis track straightness and parallelism
Tracks of 5–20 m: each rail must be straight and the pair parallel. Do single-rail straightness first, then lateral offset against one datum rail.
StraightnessMachine-tool autocollimator series ↗Robot seventh-axis rail straightness
Travel 3–10 m, typically 0.05 mm/m; transfer the datum in stages.
StraightnessGeneral-purpose electronic autocollimators ↗Robot TCP calibration
Four-pose or multi-point calibration, residual ≤ 0.1 mm; redo after tool change.
Optical AlignmentGeneral-purpose electronic autocollimators ↗Build plate and platform flatness
Repeated heating warps build plates. Check flatness before clamping; grind or replace, or first-layer failure wastes the build.
FlatnessMetrology autocollimator series ↗AM gantry and recoater plane
Layer thickness is often 20–60 μm, so gantry undulation directly varies it. Hold the 1–1.5 m travel to the 10 μm level.
StraightnessMachine-tool autocollimator series ↗Laser head squareness to the work plane
Each galvo head must be square to the plane or the melt pool shifts. A flat mirror plus a folded path aligns each head within 0.5 mrad.
Optical AlignmentWide-field electronic autocollimators ↗Distortion monitoring after stress relief
A fixed mirror logs angle through heat-up, hold and cool-down to judge whether the support scheme is adequate.
Thermal Drift & StabilityZhongji high-speed dynamic autocollimators ↗Additive gantry axis squareness
Metre-class build area, typically 0.02 mm/m; assess with layer margin.
Perpendicularity & SquarenessGeneral-purpose electronic autocollimators ↗Recoater blade to substrate parallelism
250–800 mm wide, 0.02–0.05 mm; re-check after preheat.
ParallelismGeneral-purpose electronic autocollimators ↗Dual-drive synchronisation and squareness of large-format AM gantries
Large-format (>1 m) AM gantries with dual drives need synchronisation and beam-to-guideway squareness checks to avoid layer-to-layer drift.
Perpendicularity & SquarenessZhongji fully automatic autocollimators ↗Recoater blade guideway straightness
Recoater blade guideways of metal AM machines, 200–600 mm travel, micrometre-level requirements; a bent blade guideway makes the powder layer uneven.
StraightnessZhongji automatic measurement series ↗Long core and lifter straightness
Slender cores bend and vary wall thickness. Measure free and clamped; the difference is clamping distortion.
StraightnessMachine-tool autocollimator series ↗EDM machine table flatness
Tables of precision EDM and wire-cut machines of 0.5–1 m at micrometre level; grid layout, line measurement and minimum-zone evaluation.
FlatnessMachine-tool autocollimator series ↗Guide pillar and bush coaxially and squareness
Corner pillars must be square to the parting plane and centred between halves. A centred target per pillar shows the offset that causes die-lock.
Optical AlignmentWide-field electronic autocollimators ↗Hot-runner plate and nozzle squareness
Thermal expansion tilts the hot-runner plate when hot. Cold measurement needs a predicted compensation or the gate will shift.
Small Angles & Indexing ErrorZhongji automatic measurement series ↗EDM electrode squareness to the workpiece
Micro EDM is sensitive: a 0.01 mm offset tilts the side wall. A 90° folded path corrects the C axis.
Perpendicularity & SquarenessMetrology autocollimator series ↗Mould parting-line parallelism
Moving and fixed halves of 200–800 mm need 0.005–0.02 mm. Measure each half, then check gap distribution when closed.
ParallelismMetrology autocollimator series ↗Plate certificate and uncertainty
A certificate must state grid, support, temperature, evaluation method and U. A bare 'pass' cannot be reproduced or defended.
Measurement Uncertainty BudgetMetrology autocollimator series ↗Lapping correction closed loop
Measure, map high points, plan the lapping path, measure again. Remove 1–2 μm per pass to avoid destroying the datum.
FlatnessMetrology autocollimator series ↗Granite machine bed levelling
Granite has low expansion but is brittle: support evenly at many points, then re-check after 12 h for creep.
Stage Pitch & YawMetrology autocollimator series ↗Grade 000 granite plate inspection
A 1000×1500 mm plate on a 9×7 grid after 24 h soak: rough scan for high points, then fine measurement with a minimum-zone plane.
FlatnessMetrology autocollimator series ↗Granite straight edge and square
Measure the working face by the pitch method, supporting at the two Bessel points to minimise self-weight sag.
StraightnessMetrology autocollimator series ↗Verification of granite V-blocks and straightedges
Periodic verification of granite V-blocks and straightedges for parallelism and straightness; autocollimator and optical-flat methods cross-check each other.
ParallelismMetrology autocollimator series ↗Granite square perpendicularity
300–1000 mm, typically 3–5 μm; reversal separates instrument and part error.
Perpendicularity & SquarenessGeneral-purpose electronic autocollimators ↗Straightedge straightness
1–3 m straightedges; evaluate against end points and correct for sag.
StraightnessGeneral-purpose electronic autocollimators ↗Geometry report for rebuild acceptance
List measurement conditions, raw readings, evaluation method and verdict per standard item; state why any item was not measured.
Measurement Uncertainty BudgetMetrology autocollimator series ↗Multi-pallet changer repeat positioning
Twenty pallet exchanges measuring one datum face: if the spread grows, check locating taper wear before clamping force.
ParallelismMetrology autocollimator series ↗Re-check after steel rail replacement
After fitting, measure single-rail straightness, then parallelism and equal height. Joints and bolt tightening order both shift the final curve.
StraightnessLaser autocollimators ↗Angle control during hand scraping
Measure after each scraping pass and watch the slope converge. Angles, not feeler gauges, avoid being misled by local high points.
Guideway Adjustment & VerificationMachine-tool autocollimator series ↗Headstock to tailstock coaxially
A test bar with a mirror target read near and far: the two-section difference gives the tailstock adjustment.
Optical AlignmentWide-field electronic autocollimators ↗Matched measurement during hand scraping rebuilds
During scraping rebuilds, read the angular profile after each pass to decide where and how much to scrape next until convergence.
Guideway Adjustment & VerificationMachine-tool autocollimator series ↗C-arm isocentre and beam axis coincidence
Tube focus, detector centre and rotation centre must coincide. A mirror target at several angles shows image-point drift.
Optical AlignmentWide-field electronic autocollimators ↗Cleanroom assembly bench and rail flatness
No oil mist or dust is allowed. Clean mirror and base; temperature gradients mislead more often than absolute values.
FlatnessMetrology autocollimator series ↗CT and DR gantry rotation plane squareness
The rotation axis must be square to the detector plane or reconstruction artefacts appear. Read pitch at each angular position and take the envelope.
Perpendicularity & SquarenessMetrology autocollimator series ↗Orthopaedic implant and instrument mating faces
Trial and implant mating faces affect seating force. Small parts need dedicated fixtures so clamping distortion does not dominate.
ParallelismMetrology autocollimator series ↗Surgical microscope optical path and stand stability
The stand must not drift during long procedures: log angle for 2 h after assembly. Poor counterbalance shows as slow sinking.
Stage Pitch & YawMetrology autocollimator series ↗CT gantry rotation plane and tilt monitoring
During CT gantry installation monitor rotation plane tilt and squareness; dynamic instruments sample continuously during slow rotation.
Rotary Positioning & ReversalZhongji high-speed dynamic autocollimators ↗AOI station repeatability validation
Thirty repeats on one reference panel reveal false-call rate and angle drift; insufficient warm-up is the usual early culprit.
Repeatability & Re-setup VerificationZhongji high-speed dynamic autocollimators ↗Laminator upper and lower plate parallelism
OCA lamination needs 5–20 μm between plates. Check four corners plus centre, and again under air pressure.
ParallelismWide-field electronic autocollimators ↗Laser lift-off and cutting stage straightness
Stages of 1–2 m turn straightness error into kerf offset. Measure at stable temperature with air bearings on.
StraightnessLaser autocollimators ↗Mask to substrate angle
In proximity exposure the mask-to-substrate angle shifts line width. Two points give the angle, converted through the exposure gap.
Small Angles & Indexing ErrorMetrology autocollimator series ↗Large panel and stage flatness
Substrates of 1.5–3 m need 10–50 μm over the whole area. Measure in tiles, then stitch with a common datum and overlap.
FlatnessMetrology autocollimator series ↗Parallelism of coating-line conveyor rolls
Roll parallelism on display coating lines drives substrate tracking; compare roll by roll with autocollimator and penta prism at 0.02–0.05 mm/m.
ParallelismZhongji automatic measurement series ↗Coaxiality of rudder bearing bores
Rudder bearing bores several metres apart require 0.05–0.1 mm coaxiality; a laser autocollimator establishes the datum line for bore-by-bore alignment.
Optical AlignmentLaser autocollimators ↗Deck machinery base level and squareness
Windlass and winch base level affects gear mesh and bearing life; re-check against the hull baseline after installation.
Perpendicularity & SquarenessMetrology autocollimator series ↗Hull block erection datum lines
Blocks of 20–40 m need centreline and baseline checks before erection. Long paths must avoid one-sided solar heating.
StraightnessLaser autocollimators ↗Pipe flange face parallelism and angle
Large flanges must be parallel or the gasket loads unevenly. Evaluate cold and hot conditions separately.
Small Angles & Indexing ErrorGeneral-purpose electronic autocollimators ↗Propeller shaft and rudder system relative position
Propeller shaft and rudder stock centrelines must meet the design offset. Establish one optical datum instead of chained measurements.
Optical AlignmentWide-field electronic autocollimators ↗Shaft alignment and stern-tube coaxially
Shaft lines of 8–30 m need cold alignment with allowance for hull deflection after launch. Two-section readings beat single points.
Optical AlignmentWide-field electronic autocollimators ↗Dome tracking and telescope pointing consistency
The slit centre must follow the telescope axis or air and vignetting intrude. Check with a fixed target at several azimuths.
Stage Pitch & YawMetrology autocollimator series ↗Equatorial mount polar axis and latitude angle
The polar axis must match latitude and be square to the declination axis; poor orthogonality drifts the guide star near the meridian.
Perpendicularity & SquarenessMetrology autocollimator series ↗Primary mirror axis and tube mechanical axis
Align the optical axis to the mechanical axis with a centred target. Residual error shows as a circling image during focus.
Optical AlignmentWide-field electronic autocollimators ↗Secondary support angle relative to the primary
In a Cassegrain at f/10, 12″ of secondary tilt already produces visible aberration. Back-calculate from focus position and trim.
Small Angles & Indexing ErrorMetrology autocollimator series ↗Flatness of dome and turntable rails
Dome rotation rails several metres across are measured in angular segments and integrated; typical requirement 0.1–0.3 mm over the full circle.
FlatnessMachine-tool autocollimator series ↗Primary mirror cell support attitude alignment
During assembly of large primary mirror cells, monitor mirror attitude with an autocollimator so support adjustments add no extra tilt.
Optical AlignmentGeneral-purpose electronic autocollimators ↗Beamline and end-station alignment
Every element on a tens-of-metres beamline needs referencing. Establish one master axis and transfer it section by section with folding mirrors.
Optical AlignmentWide-field electronic autocollimators ↗Angular stability in cryogenic and vacuum conditions
Uneven contraction during cool-down needs cryo-compatible mounts and windows. A full curve is worth more than a single reading.
Thermal Drift & StabilityZhongji high-speed dynamic autocollimators ↗Shared datum across instruments on one table
Several instruments share one datum: fix the reference mirror first, then connect each unit. If it moves, historical data lose comparability.
Stage Pitch & YawZhongji fully automatic autocollimators ↗Vacuum vessel flange and support faces
Flanges of 1–4 m: flatness and parallelism set seal reliability. Re-measure after lifting so self-weight deflection is not missed.
FlatnessMetrology autocollimator series ↗Flatness acceptance of optical tables
Laboratory optical tables of 1–3 m accept flatness around ±0.1 mm/m²; grid layout with autocollimator line-by-line measurement.
FlatnessMetrology autocollimator series ↗Coating and backing roll parallelism
Rolls 1.2–1.8 m long, end-to-end centre difference often ≤ 20 μm. Read both ends and adjust housings.
ParallelismGeneral-purpose electronic autocollimators ↗Module fixture flatness and hole position
600×300 mm fixture, 20 μm flatness and ±0.05 mm holes; measure the face before holes.
FlatnessGeneral-purpose electronic autocollimators ↗PV tracker mounting angle
Tracker elevation often within 0.2°; check several points, not just one.
Small Angles & Indexing ErrorGeneral-purpose electronic autocollimators ↗Stacking table flatness and level
400×400 mm table, typically 10 μm class; grid measurement with minimum-zone evaluation.
FlatnessGeneral-purpose electronic autocollimators ↗Bogie frame flatness
Frames 2.5–3.5 m, mounting-face flatness 0.3–0.5 mm; use tracker or staged autocollimation.
FlatnessGeneral-purpose electronic autocollimators ↗Track alignment and level
Track geometry uses chord methods, commonly 10 m; laser straightness screens long sections.
StraightnessLaser autocollimators ↗Wheelset coaxiality and journal runout
Coaxiality often ≤ 0.1 mm; two sections separate offset from tilt.
Coaxiality and runout by two sectionsGeneral-purpose electronic autocollimators ↗Turbine bearing housing coaxiality
Housings 3–8 m apart, cold alignment 0.02–0.05 mm; add rotor sag and thermal growth.
Coaxiality and runout by two sectionsGeneral-purpose electronic autocollimators ↗Wind tower flange parallelism
Flanges 2–4 m diameter, parallelism 0.3–0.5 mm; mark local highs.
ParallelismGeneral-purpose electronic autocollimators ↗Large equipment foundation level
Foundations over 10 m, typically 0.05 mm/m; coarse-level feet before the optical datum.
Levelling and datum establishmentGeneral-purpose electronic autocollimators ↗Press cylinder parallelism
Cylinders 0.8–1.5 m, end difference ≤ 15 μm; confirm with an impression trial.
ParallelismGeneral-purpose electronic autocollimators ↗Idler elevation and level
Idler elevation usually ±0.1 mm; record tension state.
Levelling and datum establishmentGeneral-purpose electronic autocollimators ↗Die-cutting platen flatness
Platen 1×0.7 m, 0.05 mm flatness; judge together with impression uniformity.
FlatnessGeneral-purpose electronic autocollimators ↗Ceramic guideway straightness
Travel 0.5–2 m, typically 3–5 μm/m; control clamping force.
StraightnessGeneral-purpose electronic autocollimators ↗Glass substrate flatness
1.5×1.8 m substrates; evaluate in the service support condition.
FlatnessGeneral-purpose electronic autocollimators ↗Optical window parallelism
Windows 50–200 mm, parallelism ≤ 10″; use front and rear surface reflections.
ParallelismGeneral-purpose electronic autocollimators ↗Inter-laboratory comparison
Measure one artefact on several instruments and judge with En; align methods and temperature first.
Measurement Uncertainty BudgetGeneral-purpose electronic autocollimators ↗Temperature-controlled laboratory monitoring
Log gradients, airflow and vibration; include environment in the uncertainty budget.
Thermal Drift & StabilityGeneral-purpose electronic autocollimators ↗Interim check of reference standards
Fixed stations and interval; limits from baseline mean and standard deviation.
Repeatability & Re-setup VerificationGeneral-purpose electronic autocollimators ↗No scenario under this combination. Relax the industry or stage.
Tolerance figures are common engineering ranges that indicate a selection direction, not acceptance requirements for a specific machine. The drawing, contract or applicable standard governs.