MICROCRE / OPTICAL METROLOGY400-812-7833  ·  SHANGHAI
研润 WHW
MICROCREPRECISION IN EVERY ANGLE
Home / Application atlas
APPLICATION ATLAS · 150 SCENARIOS

Application atlas

Eighteen industries broken into concrete measurement scenarios, each stating the object, typical tolerance, method and recommended series — filterable by industry and stage.

Industry
Stage

150 scenarios · open a card for the full industry note

Machine ToolsAssembly

Column-to-crossbeam squareness

Vertical machining centre column to table, or gantry column to crossbeam, 1–4 m travel. A pentaprism folds the beam through 90° so both axes separate pitch from yaw.

Perpendicularity & SquarenessMachine-tool autocollimator series ↗
Machine ToolsAssembly

Guideway straightness, horizontal and vertical plane

Bed or carriage guideways, 0.5–6 m long, typically 5–10 μm/m. Read angles at 200–500 mm spans and accumulate to a profile evaluated by minimum zone.

StraightnessMachine-tool autocollimator series ↗
Machine ToolsAssembly

Ram travel squareness to table

Travel 500–800 mm, 0.01–0.02 mm; a pentaprism reaches hidden directions.

Perpendicularity & SquarenessMachine-tool autocollimator series ↗
Machine ToolsInspection

Geometry check after machine rebuild

After scraping, rail replacement or column realignment, re-measure the GB/T items in order: straightness and squareness first, then parallelism and coaxially.

Guideway Adjustment & VerificationLaser autocollimators ↗
Machine ToolsCalibration

C-axis indexing accuracy of CNC rotary tables

Indexing error of 5-axis rotary tables by polygon and autocollimator comparison; typical acceptance ±5″ to ±15″, with compensation table output.

Rotary Positioning & ReversalGoniometers ↗
Machine ToolsCalibration

NC rotary table indexing error

Four- and five-axis tables indexed every 15° or 30°. A polygon serves as the angle reference; measure in both directions to separate backlash.

Rotary Positioning & ReversalGoniometers ↗
Machine ToolsInspection

Spindle axis parallelism to guideways

Parallelism of a boring/mill spindle axis to guideway motion, measured in two planes; typically 0.01–0.03 mm/300 mm.

ParallelismMachine-tool autocollimator series ↗
Machine ToolsAssembly

Table and mounting-face flatness

Tables 300–1200 mm and both sides of T-slots. A 5×5 to 9×9 grid measured by the pitch method is integrated; typical requirement 10–20 μm.

FlatnessMetrology autocollimator series ↗
Machine ToolsAssembly

Table rail twist

Span 300–500 mm, lateral tilt ≤ 0.02 mm/m; keep the bridge span fixed.

Guideway twist and rail height differenceMachine-tool autocollimator series ↗
Machine ToolsAssembly

Tailstock to spindle coaxiality

Two sections give offset and tilt; typically ≤ 0.02 mm with the quill clamped.

Coaxiality and runout by two sectionsMachine-tool autocollimator series ↗
AerospaceInspection

Large assembly platform flatness and equal height

Multi-point supported platforms 2–6 m need both flatness and equal support height: measure flatness first, then combine gauge blocks with the autocollimator for point heights.

FlatnessMetrology autocollimator series ↗
AerospaceInspection

Load-axis drift monitoring on fatigue rigs

Long-duration tests shift the load line as structure and actuators heat. A fixed mirror sampled continuously converts angle drift into eccentricity with a threshold alarm.

Thermal Drift & StabilityZhongji high-speed dynamic autocollimators ↗
AerospaceAssembly

Assembly jig datum faces and locator coaxially

Wing-box and fuselage jigs spanning 3–15 m. Each locator carries a mirror; one optical axis is established from the jig datum and pitch/yaw read point by point to hold 0.05 mm assembly deviation.

Optical AlignmentWide-field electronic autocollimators ↗
AerospaceAssembly

Long guide rails: straightness and twist

Moving structures on final assembly lines, 8–30 m. Long paths demand attention to air movement and floor vibration; keep span and orientation fixed and log twist separately.

StraightnessLaser autocollimators ↗
AerospaceAssembly

Optical payload mounting angle and line of sight

After a camera, star tracker or laser terminal is mounted, measure the angle between its mounting normal and the spacecraft datum, usually to arcseconds, after thermal stabilisation.

Small Angles & Indexing ErrorMetrology autocollimator series ↗
AerospaceAssembly

Perpendicularity of airborne antenna bases

Perpendicularity of radar/antenna base faces to airframe datums drives pointing accuracy; check on site with autocollimator and steering mirror.

Perpendicularity & SquarenessZhongji automatic measurement series ↗
AerospaceInspection

Composite panel contour and flatness

Panels 2–6 m, contour ±0.5 mm; photogrammetry or structured light.

FlatnessGeneral-purpose electronic autocollimators ↗
AerospaceAssembly

Wing fixture datum transfer

Multi-station transfer, closure ≤ 0.1 mm; gradients and foundation dominate.

Datum Transfer & Closure ChecksGeneral-purpose electronic autocollimators ↗
AerospaceAssembly

Coplanar alignment of wing jig locators

Wing jig locators must be coplanar or collinear over metres; align point by point with autocollimator and targets at 0.05–0.1 mm level.

Optical AlignmentZhongji fully automatic autocollimators ↗
EducationTeaching

Autocollimation demonstration

A beamsplitter and flat mirror show parallel out and focus-plane return; students turn the drum and read arcseconds to build intuition.

Small Angles & Indexing ErrorGeneral-purpose electronic autocollimators ↗
EducationTeaching

Error sources and uncertainty project

Students design a measurement, list at least six error sources, combine them, and explain why their result differs from a classmate's.

Measurement Uncertainty BudgetGeneral-purpose electronic autocollimators ↗
EducationTeaching

Grid-method flatness exercise

A 5×5 grid on a 300×300 mm plate: groups measure, swap data and evaluate separately to compare methods.

FlatnessGeneral-purpose electronic autocollimators ↗
EducationTeaching

Optical assembly and alignment practicum

From seating a lens to aligning the group, accept at element, assembly and system level so students locate error before adjusting.

Optical AlignmentWide-field electronic autocollimators ↗
EducationTeaching

Repeatability and reproducibility study

Three operators, ten repeats each: compare within and between groups to see that a good instrument is not a good system.

Repeatability & Re-setup VerificationGeneral-purpose electronic autocollimators ↗
EducationTeaching

Pitch-method straightness exercise

Eleven points at 100 mm on a 1 m rail: hand-accumulate, fit least squares, then verify in software to see angles integrate into a profile.

StraightnessGeneral-purpose electronic autocollimators ↗
EducationTeaching

Teaching lab on uncertainty evaluation

Using prism dihedral measurement as the vehicle, train repeatability statistics, component combination and k=2 expanded uncertainty reporting in 2 teaching hours.

Measurement Uncertainty BudgetGeneral-purpose electronic autocollimators ↗
Optics & OptomechanicsAssembly

Optical table levelling and post-isolation stability

Five points (four corners plus centre), level to within 10″, then log for 30 min with air isolation on to confirm no slow tilt.

Stage Pitch & YawMetrology autocollimator series ↗
Optics & OptomechanicsInspection

Substrate figure change after coating

Coating stress bows the substrate. Compare the reflected angle at the same point before and after coating to decide whether tooling compensation is needed.

Small Angles & Indexing ErrorZhongji automatic measurement series ↗
Optics & OptomechanicsAssembly

Interferometer path alignment and reference flat attitude

Reference flat attitude relative to the stage affects fringe reading; monitor alignment with an autocollimator down to arc-seconds.

Optical AlignmentGeneral-purpose electronic autocollimators ↗
Optics & OptomechanicsInspection

Lens decentre and group coaxially

Rotate the group and watch the image wobble; the radius of the traced circle gives decentre. Judge element by element so error does not accumulate in the assembly.

Optical AlignmentWide-field electronic autocollimators ↗
Optics & OptomechanicsAssembly

Mirror assembly optical axis alignment

After the mirror sits in its cell, watch the returned image and adjust pitch and yaw screws into 5–30″; lock and re-check drift.

Optical AlignmentWide-field electronic autocollimators ↗
Optics & OptomechanicsInspection

Prism and wedge angle verification

90° prisms and small wedge angles. Use a polygon or angle gauge, measure face by face, and correct for incidence angle and refractive index.

Prism & Polygon Angle ComparisonGoniometers ↗
Optics & OptomechanicsAssembly

Lens centring and axis consistency

Groups 5–200 mm, centring 5–20 μm; rotation gives image jump.

Optical AlignmentGeneral-purpose electronic autocollimators ↗
Optics & OptomechanicsInspection

Prism and wedge angle

10°–90°, typically 2–10″; autocollimator with a rotary table and closure check.

Prism & Polygon Angle ComparisonGoniometers ↗
Semiconductor EquipmentInspection

Chuck and wafer-stage flatness

150–300 mm diameter, often 1–3 μm. For small high-precision areas an autocollimator with a short base avoids an interferometer's field limit.

FlatnessMetrology autocollimator series ↗
Semiconductor EquipmentAssembly

Dual-drive gantry synchronisation and orthogonality

Unequal drives yaw the beam. Two instruments, or one multi-channel unit, read both ends and give yaw and synchronisation error directly.

Perpendicularity & SquarenessZhongji automatic measurement series ↗
Semiconductor EquipmentAssembly

Precision XY stage pitch and yaw

Strokes of 50–300 mm, often 1–5″. Sample every 10–20 mm across the travel and watch periodic components and reversal jumps.

Stage Pitch & YawZhongji fully automatic autocollimators ↗
Semiconductor EquipmentAssembly

Viewport alignment into a vacuum chamber

Measuring through a window adds refraction and figure error. Correct for incidence angle and cross-check against an external reference mirror.

Optical AlignmentWide-field electronic autocollimators ↗
Semiconductor EquipmentInspection

Vibration and repeatability check after installation

Sample one target for 10 min and read peak-to-peak angle noise and spectrum to judge foundation, isolators and air supply.

Repeatability & Re-setup VerificationZhongji high-speed dynamic autocollimators ↗
Semiconductor EquipmentInspection

Two-plane straightness acceptance of stage guideways

Granite stage guideways with a few hundred millimetres of travel at 0.5 μm level; read at 50 mm spans and evaluate both planes by minimum zone.

StraightnessMetrology autocollimator series ↗
Semiconductor EquipmentInspection

Electrostatic chuck flatness

Chucks Ø 200–300 mm, 1–2 μm; measure at working temperature and clamping.

FlatnessGeneral-purpose electronic autocollimators ↗
Semiconductor EquipmentAssembly

Lift pin synchronisation and table level

Asynchronous pins slip the wafer; check with displacement sensors or multi-point level.

Levelling and datum establishmentGeneral-purpose electronic autocollimators ↗
Automotive & New EnergyInspection

Battery tray flatness and sealing face

Trays of 1–2 m need 0.2–0.5 mm flatness along the seal groove. Sample along the sealing path, not only on a central grid.

FlatnessMetrology autocollimator series ↗
Automotive & New EnergyAssembly

Body-in-white fixture datum consistency

Across stations on the main line, one optical axis ties datum holes and locating faces together to check whether station-to-station deviation exceeds the 0.1 mm window.

Optical AlignmentWide-field electronic autocollimators ↗
Automotive & New EnergyProduction

End-of-line station cycle time and repeatability

A line takt allows 10 s per measurement. Run 30 repeats first and confirm 2σ is below one tenth of the tolerance band before release.

Repeatability & Re-setup VerificationZhongji high-speed dynamic autocollimators ↗
Automotive & New EnergyAssembly

Paint and weld robot base levelling

Base level directly affects TCP accuracy, typically within 0.2 mm/m; re-check parallelism to the track at the same time.

Small Angles & Indexing ErrorZhongji automatic measurement series ↗
Automotive & New EnergyInspection

Cylinder block main-bore coaxially

For long bores, a centred mirror target in each bore gives centre offset, faster than a mandrel and directly referenced to the first bore.

ParallelismMachine-tool autocollimator series ↗
Automotive & New EnergyProduction

Coplanarity of welding fixture datum faces

Coplanarity of BIW welding fixture datum faces drives body accuracy; check periodically by autocollimator grid method, typically 0.05–0.1 mm.

FlatnessMachine-tool autocollimator series ↗
Rail & Energy EquipmentInspection

Very long guideway joint straightness

Over 20 m, joint steps 5–10 μm; staged datum transfer with closure.

StraightnessLaser autocollimators ↗
Rail & Energy EquipmentAssembly

Large slewing ring mounting face

2–5 m diameter, 0.1–0.2 mm; record free and preloaded states.

FlatnessGeneral-purpose electronic autocollimators ↗
Rail & Energy EquipmentAssembly

Large train shaft alignment

Motor, gearbox and main machine: cold alignment must allow for thermal growth. Two-section readings give the tilt, converted to coupling face offsets.

Optical AlignmentWide-field electronic autocollimators ↗
Rail & Energy EquipmentInspection

Crane rail straightness and elevation difference

Overhead crane rails tens of metres long: straightness and rail-to-rail elevation difference affect travel; measure in segments with a long-range autocollimator.

StraightnessZhongji automatic measurement series ↗
Rail & Energy EquipmentAssembly

Foundation pads and bed levelling for large machines

Level on multiple pads to 0.1 mm/m first, re-check after grout cures, and record only after 24 h of thermal stability.

FlatnessMetrology autocollimator series ↗
Rail & Energy EquipmentInspection

Double-column gantry synchronisation and beam twist

One instrument per column, or a multi-channel unit, sampled together. Beam twist shows as opposite pitch at the two ends and directly drives tool-height difference.

Stage Pitch & YawMulti-unit electronic autocollimator systems ↗
Rail & Energy EquipmentInspection

Floor borer ram sag over extension

Ram extension of 1–3 m makes sag grow non-linearly. Read angles every 200–250 mm to obtain the deflection curve rather than an end-to-end chord.

StraightnessLaser autocollimators ↗
Rail & Energy EquipmentAssembly

Step and misalignment at welded rail joints

Rails joined from 12 m lengths past 40 m: step and kink at joints dominate. Sample densely on both sides and evaluate the kink separately.

StraightnessLaser autocollimators ↗
Rail & Energy EquipmentInspection

Multi-point synchronous monitoring of ship lifts and large platforms

Multi-point hoist synchronisation of ship lifts: monitor tilt at all points simultaneously with a multi-head autocollimator; millimetre-level dynamic deviation maps to arc-second angles.

Stage Pitch & YawMulti-unit electronic autocollimator systems ↗
Metrology & R&DCalibration

CMM guideway and column geometry

Assess straightness per axis, squareness between axes and angular motion; acceptance follows the ISO 10360 or GB/T 16857 item set.

StraightnessMetrology autocollimator series ↗
Metrology & R&DCalibration

Angle gauge and polygon verification

Use the autocollimator as the readout with a rotary stage, comparing face by face at 20±0.5 °C, three repeats per face.

Small Angles & Indexing ErrorGoniometers ↗
Metrology & R&DCalibration

Cast-iron and granite plate flatness

Grid, diagonal or circular layouts. Grade 0 plates are often 3–8 μm; soak at least 12 h and keep away from sunlight and air outlets.

FlatnessMetrology autocollimator series ↗
Metrology & R&DCalibration

Square and box squareness

Reversal removes instrument bias: average the two readings of a forward and reversed setup so the autocollimator residual drops out.

Perpendicularity & SquarenessMetrology autocollimator series ↗
Metrology & R&DCalibration

Measurement uncertainty budget and report

List indication error, span, mirror angle, temperature and repeatability, combine by root-sum-square, and state method and datum in the report.

Measurement Uncertainty BudgetMetrology autocollimator series ↗
Metrology & R&DCalibration

Angle transfer

Transfer from polygon or angle blocks to working instruments, logging uncertainty at each step.

Small Angles & Indexing ErrorGoniometers ↗
Metrology & R&DCalibration

Surface plate calibration and lapping allowance

Grid measurement gives a lapping map instead of uniform removal.

FlatnessGeneral-purpose electronic autocollimators ↗
Metrology & R&DCalibration

Indication error comparison of autocollimators

Metrology labs check in-service autocollimators with angle gauges or small-angle generators; interim checks typically every 6–12 months.

Small Angles & Indexing ErrorMetrology autocollimator series ↗
Metrology & R&DCalibration

Indexing check of roundness tester spindles

Verify angular sampling intervals of roundness tester spindles with the polygon method so harmonic analysis rests on a correct angle base; annual check.

Rotary Positioning & ReversalGoniometers ↗
Robotics & Automated AssemblyInspection

AGV and mobile platform travel attitude

Fixed mirrors along the route give the yaw angle as the vehicle passes, verifying navigation repeatability and path adherence.

Stage Pitch & YawGeneral-purpose electronic autocollimators ↗
Robotics & Automated AssemblyCalibration

Robot joint zero-position calibration aid

When restoring joint zero, verify the mechanical zero angle with a goniometer or autocollimator and target mirror; tolerance is usually within ±30″.

Small Angles & Indexing ErrorGoniometers ↗
Robotics & Automated AssemblyAssembly

Robot base levelling and re-check

Six-axis robot base, typically 0.02–0.05 mm/m. Read pitch and roll together and re-check under load for the installation record.

Stage Pitch & YawGeneral-purpose electronic autocollimators ↗
Robotics & Automated AssemblyAssembly

End-effector mounting attitude

The angle between flange and tooling datum sets grasp attitude. Attach a flat mirror to the flange and read the two-axis deviation directly.

Small Angles & Indexing ErrorZhongji automatic measurement series ↗
Robotics & Automated AssemblyInspection

Robot joint angular repeatability

Thirty round trips to one commanded pose give the angular spread. Compare with the rated repeatability to flag gearbox wear.

Repeatability & Re-setup VerificationZhongji high-speed dynamic autocollimators ↗
Robotics & Automated AssemblyAssembly

Seventh-axis track straightness and parallelism

Tracks of 5–20 m: each rail must be straight and the pair parallel. Do single-rail straightness first, then lateral offset against one datum rail.

StraightnessMachine-tool autocollimator series ↗
Robotics & Automated AssemblyAssembly

Robot seventh-axis rail straightness

Travel 3–10 m, typically 0.05 mm/m; transfer the datum in stages.

StraightnessGeneral-purpose electronic autocollimators ↗
Robotics & Automated AssemblyCalibration

Robot TCP calibration

Four-pose or multi-point calibration, residual ≤ 0.1 mm; redo after tool change.

Optical AlignmentGeneral-purpose electronic autocollimators ↗
Additive Manufacturing & Laser ProcessingInspection

Build plate and platform flatness

Repeated heating warps build plates. Check flatness before clamping; grind or replace, or first-layer failure wastes the build.

FlatnessMetrology autocollimator series ↗
Additive Manufacturing & Laser ProcessingAssembly

AM gantry and recoater plane

Layer thickness is often 20–60 μm, so gantry undulation directly varies it. Hold the 1–1.5 m travel to the 10 μm level.

StraightnessMachine-tool autocollimator series ↗
Additive Manufacturing & Laser ProcessingAssembly

Laser head squareness to the work plane

Each galvo head must be square to the plane or the melt pool shifts. A flat mirror plus a folded path aligns each head within 0.5 mrad.

Optical AlignmentWide-field electronic autocollimators ↗
Additive Manufacturing & Laser ProcessingInspection

Distortion monitoring after stress relief

A fixed mirror logs angle through heat-up, hold and cool-down to judge whether the support scheme is adequate.

Thermal Drift & StabilityZhongji high-speed dynamic autocollimators ↗
Additive Manufacturing & Laser ProcessingAssembly

Additive gantry axis squareness

Metre-class build area, typically 0.02 mm/m; assess with layer margin.

Perpendicularity & SquarenessGeneral-purpose electronic autocollimators ↗
Additive Manufacturing & Laser ProcessingAssembly

Recoater blade to substrate parallelism

250–800 mm wide, 0.02–0.05 mm; re-check after preheat.

ParallelismGeneral-purpose electronic autocollimators ↗
Additive Manufacturing & Laser ProcessingAssembly

Dual-drive synchronisation and squareness of large-format AM gantries

Large-format (>1 m) AM gantries with dual drives need synchronisation and beam-to-guideway squareness checks to avoid layer-to-layer drift.

Perpendicularity & SquarenessZhongji fully automatic autocollimators ↗
Additive Manufacturing & Laser ProcessingProduction

Recoater blade guideway straightness

Recoater blade guideways of metal AM machines, 200–600 mm travel, micrometre-level requirements; a bent blade guideway makes the powder layer uneven.

StraightnessZhongji automatic measurement series ↗
Precision Moulds & ToolingInspection

Long core and lifter straightness

Slender cores bend and vary wall thickness. Measure free and clamped; the difference is clamping distortion.

StraightnessMachine-tool autocollimator series ↗
Precision Moulds & ToolingInspection

EDM machine table flatness

Tables of precision EDM and wire-cut machines of 0.5–1 m at micrometre level; grid layout, line measurement and minimum-zone evaluation.

FlatnessMachine-tool autocollimator series ↗
Precision Moulds & ToolingAssembly

Guide pillar and bush coaxially and squareness

Corner pillars must be square to the parting plane and centred between halves. A centred target per pillar shows the offset that causes die-lock.

Optical AlignmentWide-field electronic autocollimators ↗
Precision Moulds & ToolingInspection

Hot-runner plate and nozzle squareness

Thermal expansion tilts the hot-runner plate when hot. Cold measurement needs a predicted compensation or the gate will shift.

Small Angles & Indexing ErrorZhongji automatic measurement series ↗
Precision Moulds & ToolingAssembly

EDM electrode squareness to the workpiece

Micro EDM is sensitive: a 0.01 mm offset tilts the side wall. A 90° folded path corrects the C axis.

Perpendicularity & SquarenessMetrology autocollimator series ↗
Precision Moulds & ToolingInspection

Mould parting-line parallelism

Moving and fixed halves of 200–800 mm need 0.005–0.02 mm. Measure each half, then check gap distribution when closed.

ParallelismMetrology autocollimator series ↗
Granite & Precision BasesCalibration

Plate certificate and uncertainty

A certificate must state grid, support, temperature, evaluation method and U. A bare 'pass' cannot be reproduced or defended.

Measurement Uncertainty BudgetMetrology autocollimator series ↗
Granite & Precision BasesProduction

Lapping correction closed loop

Measure, map high points, plan the lapping path, measure again. Remove 1–2 μm per pass to avoid destroying the datum.

FlatnessMetrology autocollimator series ↗
Granite & Precision BasesAssembly

Granite machine bed levelling

Granite has low expansion but is brittle: support evenly at many points, then re-check after 12 h for creep.

Stage Pitch & YawMetrology autocollimator series ↗
Granite & Precision BasesInspection

Grade 000 granite plate inspection

A 1000×1500 mm plate on a 9×7 grid after 24 h soak: rough scan for high points, then fine measurement with a minimum-zone plane.

FlatnessMetrology autocollimator series ↗
Granite & Precision BasesInspection

Granite straight edge and square

Measure the working face by the pitch method, supporting at the two Bessel points to minimise self-weight sag.

StraightnessMetrology autocollimator series ↗
Granite & Precision BasesInspection

Verification of granite V-blocks and straightedges

Periodic verification of granite V-blocks and straightedges for parallelism and straightness; autocollimator and optical-flat methods cross-check each other.

ParallelismMetrology autocollimator series ↗
Granite & Precision BasesInspection

Granite square perpendicularity

300–1000 mm, typically 3–5 μm; reversal separates instrument and part error.

Perpendicularity & SquarenessGeneral-purpose electronic autocollimators ↗
Granite & Precision BasesInspection

Straightedge straightness

1–3 m straightedges; evaluate against end points and correct for sag.

StraightnessGeneral-purpose electronic autocollimators ↗
Machine Rebuild & MaintenanceCalibration

Geometry report for rebuild acceptance

List measurement conditions, raw readings, evaluation method and verdict per standard item; state why any item was not measured.

Measurement Uncertainty BudgetMetrology autocollimator series ↗
Machine Rebuild & MaintenanceInspection

Multi-pallet changer repeat positioning

Twenty pallet exchanges measuring one datum face: if the spread grows, check locating taper wear before clamping force.

ParallelismMetrology autocollimator series ↗
Machine Rebuild & MaintenanceAssembly

Re-check after steel rail replacement

After fitting, measure single-rail straightness, then parallelism and equal height. Joints and bolt tightening order both shift the final curve.

StraightnessLaser autocollimators ↗
Machine Rebuild & MaintenanceInspection

Angle control during hand scraping

Measure after each scraping pass and watch the slope converge. Angles, not feeler gauges, avoid being misled by local high points.

Guideway Adjustment & VerificationMachine-tool autocollimator series ↗
Machine Rebuild & MaintenanceAssembly

Headstock to tailstock coaxially

A test bar with a mirror target read near and far: the two-section difference gives the tailstock adjustment.

Optical AlignmentWide-field electronic autocollimators ↗
Machine Rebuild & MaintenanceAssembly

Matched measurement during hand scraping rebuilds

During scraping rebuilds, read the angular profile after each pass to decide where and how much to scrape next until convergence.

Guideway Adjustment & VerificationMachine-tool autocollimator series ↗
Medical Equipment AssemblyAssembly

C-arm isocentre and beam axis coincidence

Tube focus, detector centre and rotation centre must coincide. A mirror target at several angles shows image-point drift.

Optical AlignmentWide-field electronic autocollimators ↗
Medical Equipment AssemblyInspection

Cleanroom assembly bench and rail flatness

No oil mist or dust is allowed. Clean mirror and base; temperature gradients mislead more often than absolute values.

FlatnessMetrology autocollimator series ↗
Medical Equipment AssemblyAssembly

CT and DR gantry rotation plane squareness

The rotation axis must be square to the detector plane or reconstruction artefacts appear. Read pitch at each angular position and take the envelope.

Perpendicularity & SquarenessMetrology autocollimator series ↗
Medical Equipment AssemblyInspection

Orthopaedic implant and instrument mating faces

Trial and implant mating faces affect seating force. Small parts need dedicated fixtures so clamping distortion does not dominate.

ParallelismMetrology autocollimator series ↗
Medical Equipment AssemblyAssembly

Surgical microscope optical path and stand stability

The stand must not drift during long procedures: log angle for 2 h after assembly. Poor counterbalance shows as slow sinking.

Stage Pitch & YawMetrology autocollimator series ↗
Medical Equipment AssemblyAssembly

CT gantry rotation plane and tilt monitoring

During CT gantry installation monitor rotation plane tilt and squareness; dynamic instruments sample continuously during slow rotation.

Rotary Positioning & ReversalZhongji high-speed dynamic autocollimators ↗
Display & Electronics ManufacturingProduction

AOI station repeatability validation

Thirty repeats on one reference panel reveal false-call rate and angle drift; insufficient warm-up is the usual early culprit.

Repeatability & Re-setup VerificationZhongji high-speed dynamic autocollimators ↗
Display & Electronics ManufacturingAssembly

Laminator upper and lower plate parallelism

OCA lamination needs 5–20 μm between plates. Check four corners plus centre, and again under air pressure.

ParallelismWide-field electronic autocollimators ↗
Display & Electronics ManufacturingAssembly

Laser lift-off and cutting stage straightness

Stages of 1–2 m turn straightness error into kerf offset. Measure at stable temperature with air bearings on.

StraightnessLaser autocollimators ↗
Display & Electronics ManufacturingInspection

Mask to substrate angle

In proximity exposure the mask-to-substrate angle shifts line width. Two points give the angle, converted through the exposure gap.

Small Angles & Indexing ErrorMetrology autocollimator series ↗
Display & Electronics ManufacturingInspection

Large panel and stage flatness

Substrates of 1.5–3 m need 10–50 μm over the whole area. Measure in tiles, then stitch with a common datum and overlap.

FlatnessMetrology autocollimator series ↗
Display & Electronics ManufacturingProduction

Parallelism of coating-line conveyor rolls

Roll parallelism on display coating lines drives substrate tracking; compare roll by roll with autocollimator and penta prism at 0.02–0.05 mm/m.

ParallelismZhongji automatic measurement series ↗
Shipbuilding & Marine EquipmentAssembly

Coaxiality of rudder bearing bores

Rudder bearing bores several metres apart require 0.05–0.1 mm coaxiality; a laser autocollimator establishes the datum line for bore-by-bore alignment.

Optical AlignmentLaser autocollimators ↗
Shipbuilding & Marine EquipmentAssembly

Deck machinery base level and squareness

Windlass and winch base level affects gear mesh and bearing life; re-check against the hull baseline after installation.

Perpendicularity & SquarenessMetrology autocollimator series ↗
Shipbuilding & Marine EquipmentAssembly

Hull block erection datum lines

Blocks of 20–40 m need centreline and baseline checks before erection. Long paths must avoid one-sided solar heating.

StraightnessLaser autocollimators ↗
Shipbuilding & Marine EquipmentInspection

Pipe flange face parallelism and angle

Large flanges must be parallel or the gasket loads unevenly. Evaluate cold and hot conditions separately.

Small Angles & Indexing ErrorGeneral-purpose electronic autocollimators ↗
Shipbuilding & Marine EquipmentAssembly

Propeller shaft and rudder system relative position

Propeller shaft and rudder stock centrelines must meet the design offset. Establish one optical datum instead of chained measurements.

Optical AlignmentWide-field electronic autocollimators ↗
Shipbuilding & Marine EquipmentAssembly

Shaft alignment and stern-tube coaxially

Shaft lines of 8–30 m need cold alignment with allowance for hull deflection after launch. Two-section readings beat single points.

Optical AlignmentWide-field electronic autocollimators ↗
Astronomy & Large Optical SystemsAssembly

Dome tracking and telescope pointing consistency

The slit centre must follow the telescope axis or air and vignetting intrude. Check with a fixed target at several azimuths.

Stage Pitch & YawMetrology autocollimator series ↗
Astronomy & Large Optical SystemsAssembly

Equatorial mount polar axis and latitude angle

The polar axis must match latitude and be square to the declination axis; poor orthogonality drifts the guide star near the meridian.

Perpendicularity & SquarenessMetrology autocollimator series ↗
Astronomy & Large Optical SystemsAssembly

Primary mirror axis and tube mechanical axis

Align the optical axis to the mechanical axis with a centred target. Residual error shows as a circling image during focus.

Optical AlignmentWide-field electronic autocollimators ↗
Astronomy & Large Optical SystemsAssembly

Secondary support angle relative to the primary

In a Cassegrain at f/10, 12″ of secondary tilt already produces visible aberration. Back-calculate from focus position and trim.

Small Angles & Indexing ErrorMetrology autocollimator series ↗
Astronomy & Large Optical SystemsInspection

Flatness of dome and turntable rails

Dome rotation rails several metres across are measured in angular segments and integrated; typical requirement 0.1–0.3 mm over the full circle.

FlatnessMachine-tool autocollimator series ↗
Astronomy & Large Optical SystemsAssembly

Primary mirror cell support attitude alignment

During assembly of large primary mirror cells, monitor mirror attitude with an autocollimator so support adjustments add no extra tilt.

Optical AlignmentGeneral-purpose electronic autocollimators ↗
Research Facilities & Beamline AssemblyAssembly

Beamline and end-station alignment

Every element on a tens-of-metres beamline needs referencing. Establish one master axis and transfer it section by section with folding mirrors.

Optical AlignmentWide-field electronic autocollimators ↗
Research Facilities & Beamline AssemblyInspection

Angular stability in cryogenic and vacuum conditions

Uneven contraction during cool-down needs cryo-compatible mounts and windows. A full curve is worth more than a single reading.

Thermal Drift & StabilityZhongji high-speed dynamic autocollimators ↗
Research Facilities & Beamline AssemblyAssembly

Shared datum across instruments on one table

Several instruments share one datum: fix the reference mirror first, then connect each unit. If it moves, historical data lose comparability.

Stage Pitch & YawZhongji fully automatic autocollimators ↗
Research Facilities & Beamline AssemblyAssembly

Vacuum vessel flange and support faces

Flanges of 1–4 m: flatness and parallelism set seal reliability. Re-measure after lifting so self-weight deflection is not missed.

FlatnessMetrology autocollimator series ↗
Research Facilities & Beamline AssemblyInspection

Flatness acceptance of optical tables

Laboratory optical tables of 1–3 m accept flatness around ±0.1 mm/m²; grid layout with autocollimator line-by-line measurement.

FlatnessMetrology autocollimator series ↗
New energy and battery manufacturingAssembly

Coating and backing roll parallelism

Rolls 1.2–1.8 m long, end-to-end centre difference often ≤ 20 μm. Read both ends and adjust housings.

ParallelismGeneral-purpose electronic autocollimators ↗
New energy and battery manufacturingInspection

Module fixture flatness and hole position

600×300 mm fixture, 20 μm flatness and ±0.05 mm holes; measure the face before holes.

FlatnessGeneral-purpose electronic autocollimators ↗
New energy and battery manufacturingAssembly

PV tracker mounting angle

Tracker elevation often within 0.2°; check several points, not just one.

Small Angles & Indexing ErrorGeneral-purpose electronic autocollimators ↗
New energy and battery manufacturingAssembly

Stacking table flatness and level

400×400 mm table, typically 10 μm class; grid measurement with minimum-zone evaluation.

FlatnessGeneral-purpose electronic autocollimators ↗
Rail transit and rolling stockAssembly

Bogie frame flatness

Frames 2.5–3.5 m, mounting-face flatness 0.3–0.5 mm; use tracker or staged autocollimation.

FlatnessGeneral-purpose electronic autocollimators ↗
Rail transit and rolling stockInspection

Track alignment and level

Track geometry uses chord methods, commonly 10 m; laser straightness screens long sections.

StraightnessLaser autocollimators ↗
Rail transit and rolling stockInspection

Wheelset coaxiality and journal runout

Coaxiality often ≤ 0.1 mm; two sections separate offset from tilt.

Coaxiality and runout by two sectionsGeneral-purpose electronic autocollimators ↗
Power generation equipmentAssembly

Turbine bearing housing coaxiality

Housings 3–8 m apart, cold alignment 0.02–0.05 mm; add rotor sag and thermal growth.

Coaxiality and runout by two sectionsGeneral-purpose electronic autocollimators ↗
Power generation equipmentInspection

Wind tower flange parallelism

Flanges 2–4 m diameter, parallelism 0.3–0.5 mm; mark local highs.

ParallelismGeneral-purpose electronic autocollimators ↗
Power generation equipmentAssembly

Large equipment foundation level

Foundations over 10 m, typically 0.05 mm/m; coarse-level feet before the optical datum.

Levelling and datum establishmentGeneral-purpose electronic autocollimators ↗
Printing and packagingAssembly

Press cylinder parallelism

Cylinders 0.8–1.5 m, end difference ≤ 15 μm; confirm with an impression trial.

ParallelismGeneral-purpose electronic autocollimators ↗
Printing and packagingAssembly

Idler elevation and level

Idler elevation usually ±0.1 mm; record tension state.

Levelling and datum establishmentGeneral-purpose electronic autocollimators ↗
Printing and packagingInspection

Die-cutting platen flatness

Platen 1×0.7 m, 0.05 mm flatness; judge together with impression uniformity.

FlatnessGeneral-purpose electronic autocollimators ↗
Glass and technical ceramicsInspection

Ceramic guideway straightness

Travel 0.5–2 m, typically 3–5 μm/m; control clamping force.

StraightnessGeneral-purpose electronic autocollimators ↗
Glass and technical ceramicsInspection

Glass substrate flatness

1.5×1.8 m substrates; evaluate in the service support condition.

FlatnessGeneral-purpose electronic autocollimators ↗
Glass and technical ceramicsInspection

Optical window parallelism

Windows 50–200 mm, parallelism ≤ 10″; use front and rear surface reflections.

ParallelismGeneral-purpose electronic autocollimators ↗
Testing and calibration laboratoriesCalibration

Inter-laboratory comparison

Measure one artefact on several instruments and judge with En; align methods and temperature first.

Measurement Uncertainty BudgetGeneral-purpose electronic autocollimators ↗
Testing and calibration laboratoriesCalibration

Temperature-controlled laboratory monitoring

Log gradients, airflow and vibration; include environment in the uncertainty budget.

Thermal Drift & StabilityGeneral-purpose electronic autocollimators ↗
Testing and calibration laboratoriesCalibration

Interim check of reference standards

Fixed stations and interval; limits from baseline mean and standard deviation.

Repeatability & Re-setup VerificationGeneral-purpose electronic autocollimators ↗

Tolerance figures are common engineering ranges that indicate a selection direction, not acceptance requirements for a specific machine. The drawing, contract or applicable standard governs.