Angle and alignment

Photoelectric autocollimation

Reads the tiny tilt of a mirror from a returned collimated beam: the base method for straightness, squareness and parallelism.

±10′ (optional ±30′ / ±1000″) · 0.1″–0.5″ (typical, depends on range and calibration)
Angle and alignment

Laser autocollimation

Laser source instead of halogen: stable return beam over long distances and wide ranges.

±30′ / ±1000″ (model dependent) · 0.2″–1″ (typical)
Angle and alignment

Regular polygon mirror method

A polygon mirror with calibrated face angles plus an autocollimator gives full-circle indexing calibration.

0°–360°, 8/12/24/36 faces · 0.3″–1″ (including polygon grade)
Angle and alignment

Pentaprism and optical square

Turns a 90° relationship into beam direction for axis squareness and large-frame right angles.

90°±5″ (device accuracy) · 1″–5″ (system)
Angle and alignment

Collimator and alignment telescope

Provides an infinity target for boresight consistency, multi-mirror co-alignment and long-range pointing.

focal length 300–2000 mm · 2″–10″
Angle and alignment

Rotary encoder comparison

Uses a higher-grade encoder or polygon as reference to evaluate full-circle error of tables and indexing mechanisms.

0°–360° · 0.5″–2″ (system)
Interferometry and displacement

Laser interferometry (displacement)

The wavelength is the scale: the reference method for axis positioning, repeatability and backlash.

0–30 m (configuration dependent) · 0.5 ppm (compensated, typical)
Interferometry and displacement

Laser angle interferometry

A double-mirror path converts angle into path difference for long-travel angle and straightness work.

±10° (small-angle mode) · 0.2″+0.1″/m
Interferometry and displacement

White-light interferometry

Short coherence gives nanometre vertical resolution for surface topography.

0.1 mm–10 mm (vertical) · 0.05–0.5 μm (depends on objective and calibration)
Interferometry and displacement

Laser tracking

Range plus angle gives 3D point coordinates over large volumes.

0.5–80 m · 15 μm+6 μm/m (typical)
Interferometry and displacement

FMCW laser radar

Target-free ranging and angular measurement on diffuse surfaces for large parts.

0.5–30 m · 25 μm+10 μm/m (typical)
Interferometry and displacement

Laser straightness with PSD

A laser beam is the straight datum; a position-sensitive detector reads deviation along long guideways.

0–30 m · 0.5 μm+1 μm/m
Coordinates and 3D

Contact CMM

Point-by-point probing with fitting algorithms for size and GD&T.

0.1–3 m (stroke) · 1.5+L/350 μm (typical)
Coordinates and 3D

Articulated arm CMM

Portable multi-joint arm for on-site work and parts that cannot be moved.

1.2–4.5 m (sphere diameter) · 0.03–0.1 mm (typical)
Coordinates and 3D

Industrial photogrammetry

Coded targets imaged from several angles give large-volume 3D coordinates by intersection.

1–100 m · 0.05 mm+0.02 mm/m
Coordinates and 3D

Structured-light fringe projection

Projected fringes and phase decoding give dense point clouds for freeform surfaces.

50–1000 mm (single view) · 0.01–0.05 mm (typical)
Coordinates and 3D

Laser triangulation scanning

A line laser scanned across the part suits profiles, weld seams and in-line inspection.

10–1000 mm · 0.01–0.1 mm (typical)
Coordinates and 3D

Industrial X-ray CT

Reconstructs internal structure as voxels for internal dimensions and defects.

Ø 10–500 mm · 5–50 μm (depends on magnification)
Coordinates and 3D

Vision measurement

Telecentric optics and high-resolution cameras measure 2D contours and hole positions quickly and without contact.

50×50–600×600 mm · 1–5 μm (typical)
Surface and form

Stylus profilometry

A diamond stylus traces the surface: the classic route to roughness and waviness.

Ra 0.01–100 μm · 5%–10% (Ra)
Surface and form

Chromatic confocal sensing

Dispersion maps wavelength to focus, giving high-resolution non-contact distance and thickness.

0.1–30 mm · 0.01%–0.1% FS
Surface and form

Focus variation microscopy

Through-focus stacking combines large depth of field with fine resolution for tools, moulds and additive surfaces.

0.1–100 mm (field of view) · 0.1–1 μm
Surface and form

Deflectometry

Distortion of reflected fringes reveals the form of large specular surfaces with high sensitivity.

0.1–3 m · λ/20–λ/5 (aperture dependent)
Motion and machine performance

Ballbar circular test

A telescoping bar measures a circular path to diagnose servo mismatch and reversal spikes.

Ø 100–600 mm · ±1–2 μm (system)
Motion and machine performance

R-test for five-axis kinematics

Three displacement sensors track a sphere centre to evaluate five-axis rotary and linear axis errors together.

Ø 10–30 mm sphere · 2–5 μm (volumetric)
Motion and machine performance

Laser step gauge and diagonal test

Body-diagonal tests give a fast volumetric accuracy check on large machines.

0.5–10 m (diagonal) · 5–20 μm (volumetric)
Motion and machine performance

Rotary axis geometric check

ISO 230-7 checks centre, tilt and axial/radial error motions of rotary axes.

0°–360° · 1–5 μm / 2–5″
Motion and machine performance

Thermal behaviour and imaging

Relates temperature rise to structural distortion, explaining why morning and afternoon results differ.

-20–1500 °C · ±1–2 °C (temperature measurement)
NDT and internal defects

Ultrasonic testing

High-frequency sound finds internal defects and wall thickness in metals and composites.

1–500 mm (steel) · ±0.1 mm (wall thickness)
NDT and internal defects

Eddy current testing

An alternating field induces eddy currents to find cracks, delamination and conductivity changes.

0–10 mm (penetration depth) · reference block dependent
Motion and machine performance

Laser Doppler vibrometry

Non-contact velocity and displacement measurement for spindles, stages and precision equipment.

0–30 m · 1%–3%

Capability comparison

TechniqueCategoryRangeResolutionTypical uncertainty
Photoelectric autocollimationAngle and alignment±10′ (optional ±30′ / ±1000″)0.001″ (digital)0.1″–0.5″ (typical, depends on range and calibration)
Laser autocollimationAngle and alignment±30′ / ±1000″ (model dependent)0.001″0.2″–1″ (typical)
Regular polygon mirror methodAngle and alignment0°–360°, 8/12/24/36 faces0.1″ (with 0.1″ autocollimator)0.3″–1″ (including polygon grade)
Pentaprism and optical squareAngle and alignment90°±5″ (device accuracy)depends on autocollimator1″–5″ (system)
Collimator and alignment telescopeAngle and alignmentfocal length 300–2000 mm1″–5″ (visual)/ 0.1″ (photoelectric)2″–10″
Rotary encoder comparisonAngle and alignment0°–360°0.01″–0.1″0.5″–2″ (system)
Laser interferometry (displacement)Interferometry and displacement0–30 m (configuration dependent)1 nm (resolution)0.5 ppm (compensated, typical)
Laser angle interferometryInterferometry and displacement±10° (small-angle mode)0.01″0.2″+0.1″/m
White-light interferometryInterferometry and displacement0.1 mm–10 mm (vertical)0.01 nm (vertical)0.05–0.5 μm (depends on objective and calibration)
Phase-shifting interferometry and optical flatsInterferometry and displacementØ 25–300 mmλ/1000 (phase)λ/20–λ/100 (form)
Laser trackingInterferometry and displacement0.5–80 m1 μm (ranging)15 μm+6 μm/m (typical)
FMCW laser radarInterferometry and displacement0.5–30 m10 μm25 μm+10 μm/m (typical)
Laser straightness with PSDInterferometry and displacement0–30 m0.1 μm0.5 μm+1 μm/m
Contact CMMCoordinates and 3D0.1–3 m (stroke)0.1 μm (grating)1.5+L/350 μm (typical)
Articulated arm CMMCoordinates and 3D1.2–4.5 m (sphere diameter)0.01 mm0.03–0.1 mm (typical)
Industrial photogrammetryCoordinates and 3D1–100 m0.02 mm (point)0.05 mm+0.02 mm/m
Structured-light fringe projectionCoordinates and 3D50–1000 mm (single view)0.01 mm (point spacing)0.01–0.05 mm (typical)
Laser triangulation scanningCoordinates and 3D10–1000 mm0.005 mm (profile)0.01–0.1 mm (typical)
Industrial X-ray CTCoordinates and 3DØ 10–500 mm5 μm (voxel)5–50 μm (depends on magnification)
Vision measurementCoordinates and 3D50×50–600×600 mm0.1 μm (pixel scale)1–5 μm (typical)
Stylus profilometrySurface and formRa 0.01–100 μm1 nm (vertical)5%–10% (Ra)
Chromatic confocal sensingSurface and form0.1–30 mm1 nm0.01%–0.1% FS
Focus variation microscopySurface and form0.1–100 mm (field of view)0.01 μm (vertical)0.1–1 μm
DeflectometrySurface and form0.1–3 m0.1 μm (height)λ/20–λ/5 (aperture dependent)
Ballbar circular testMotion and machine performanceØ 100–600 mm0.1 μm±1–2 μm (system)
R-test for five-axis kinematicsMotion and machine performanceØ 10–30 mm sphere0.1 μm2–5 μm (volumetric)
Laser step gauge and diagonal testMotion and machine performance0.5–10 m (diagonal)0.5 μm5–20 μm (volumetric)
Rotary axis geometric checkMotion and machine performance0°–360°0.1 μm / 0.1″1–5 μm / 2–5″
Thermal behaviour and imagingMotion and machine performance-20–1500 °C0.05 °C±1–2 °C (temperature measurement)
Ultrasonic testingNDT and internal defects1–500 mm (steel)0.1 mm±0.1 mm (wall thickness)
Eddy current testingNDT and internal defects0–10 mm (penetration depth)0.1 mm (crack)reference block dependent
Laser Doppler vibrometryMotion and machine performance0–30 m0.01 μm/s1%–3%