MICROCRE / OPTICAL METROLOGY400-812-7833  ·  SHANGHAI
研润 WHW
MICROCREPRECISION IN EVERY ANGLE
Home / Semiconductor stage guideways: evaluating straightness in two planes
CASE 15 · TEACHING DATA

Semiconductor stage guideways: evaluating straightness in two planes

Vertical-plane straightness of a wafer stage guideway affects the focal plane; horizontal-plane straightness affects overlay. Measure and evaluate the two planes separately — never merge them into one "total straightness".

ObjectGranite stage guideway, 400 mm effective travel
Typical requirementStraightness ≤ 0.5 μm over full travel, per plane
Segmentation50 mm span, 8 segments / 9 points, 5 readings averaged per point
Instrument0.1″ class dual-axis autocollimator
h_i = sum L tan(theta)

Setup: map the two axes to the two planes

The vertical axis of a dual-axis autocollimator reads angular change in the vertical plane, the horizontal axis in the horizontal plane. Seat the mirror carrier flat on the guideway contact surface with side location so the span direction follows the guideway.

Place the instrument on a stable table along the guideway extension, axis at mirror-centre height, avoiding large pitch angles that add cosine error.

Readings and reconstruction: segment integration

Record both axes at each span; integrate the vertical sequence into the vertical profile and the horizontal sequence into the horizontal profile. Δh = L·tan(θ): at a 50 mm span, 1″ equals about 0.24 μm of height difference.

Teaching example: eight vertical-axis readings (″): 0.0, +0.4, +0.7, +0.3, -0.2, -0.5, -0.3, -0.1; the integrated profile shows about 0.38 μm peak-to-valley.

Evaluation: minimum zone, not end-point line

Semiconductor practice evaluates by minimum zone: two parallel lines bracket the profile and the smallest separation is the straightness. End-point evaluation reads high, least-squares midline reads low; the report must state the algorithm used.

Conclude per plane: in this example 0.38 μm vertical and 0.29 μm horizontal (teaching values), both within 0.5 μm.

Case workflow, animated

ABCDΔ₄₁Closure c = ΣΔ should approach 0; c/4 is a conditional correctionSchematic · not to scale · not measured data
1 / 4
  1. Confirm the task and datum
  2. Lay out stations by span
  3. Acquire readings and convert
  4. Evaluate and verify

The animation follows the station layout and calculation order of this case. Values are teaching data.

ConclusionEvaluated separately: 0.38 μm vertical, 0.29 μm horizontal, both within the 0.5 μm requirement; algorithm stated as minimum zone. (Teaching example data)

Case data are teaching assumptions. Stage acceptance follows the equipment manufacturer agreement; a 0.1″ class instrument resolves about 0.02 μm at a 50 mm span, and the achievable uncertainty depends on environment and repeatability.

Recommended instruments