Least squares versus minimum zone

Software defaults to least-squares residual peak-to-valley while drawings often specify minimum zone. The difference can reach 20–30%, so mixing them invalidates the decision.

h_i = sum L tan(theta)
Least squares: min Σ(zᵢ − axᵢ − byᵢ − c)²; minimum zone: min (max rᵢ − min rᵢ)

Animated explanation

Minimum zone: two parallel planesLeast squares: minimal residual sumDifferent results — state the method in the reportSchematic · not to scale · not measured data
1 / 4
  1. Establish the geometry
  2. See how one reading forms
  3. Change a condition and observe
  4. Return to the formula and its limits

The animation explains relationships and directions. Read numbers from the formula, the standard and your records.

When each applies

Least squares suits trending and process analysis: stable and insensitive to single points.

Minimum zone matches the ISO 1101 containment requirement and is used for conformance; it needs an optimiser and is sampling-sensitive.

State it in the report

State method, datum, filter and sampling density. A number without a method cannot be verified.

If conclusions differ, the drawing or contract method governs; report the other for reference.