Animated explanation
- Establish the geometry
- See how one reading forms
- Change a condition and observe
- Return to the formula and its limits
The animation explains relationships and directions. Read numbers from the formula, the standard and your records.
Noise or signal first
Twenty readings at one position: symmetric scatter means noise, monotonic drift means thermal or mechanical settling, isolated spikes point to supply, grounding or source.
Do not filter before you know which one you have.
Averaging pays by the square root
0.6″ random noise falls to 0.15″ with 16 averages, at 16× the time cost, during which drift enters.
For slow processes, long averaging averages away real change; use medians or piecewise fits.
Keep the raw data
Reports may show averages, but keep the raw series: only raw data settles a dispute.
Related methods and industries
Recommended instruments

Dual-axis electronic autocollimator accuracy 1″ maximum measuring distance 10m

Dual-axis electronic autocollimator accuracy 1″ maximum measuring distance 20m