Conditional product-standard candidate, only for the relevant design; model applicability is unconfirmed.
Official directory ↗Goniometers

Select using tolerance, distance, references and environmental conditions.
PDF for reading, editable Word; generated from the same source data.
The goniometer is a precision angular measuring instrument for research institutions, factories, aerospace and metrology. It normally combines an autocollimator, a high-precision rotary table and a control system. Electronic goniometers provide real-time measurement display for convenient reading and recording. Small angular changes are detected by an angle sensor, processed by the control system and sent to the display terminal.
Optical manufacturing: prism accuracy inspection and process quality control. Metrology: calibration and verification of angular reference artefacts and angle-measuring equipment. Scientific research: experimental angle measurements.
| System measurement accuracy | ≤ ±1″ |
| System measurement repeatability | ≤ 0.5″ |
| Objective focal length | 300mm |
| Display resolution | 0.01″ ( adjustable ) |
| Autocollimator central-range error (±100″) | ±0.1″ |
| Rotary-table positioning error | ≤ ±1″ |
| Rotary-table maximum load | 30KG |
| Rotary-table drive | Motorized |
| Measurement range | 0-360° |
| Installation configuration | Separate modules or an integrated measurement system on a marble platform |
Original source ↗ · 2026-11-14
Resolution is not accuracy. Preserve range conditions and confirm missing data with the engineering team.
Four steps: where the light comes from, where it returns, how the reading appears.
The animation shows the optical path and how a reading arises. It does not represent the resolution, range or accuracy of this model.
Four- and five-axis tables indexed every 15° or 30°. A polygon serves as the angle reference; measure in both directions to separate backlash.
Rotary Positioning & Reversal↗90° prisms and small wedge angles. Use a polygon or angle gauge, measure face by face, and correct for incidence angle and refractive index.
Prism & Polygon Angle Comparison↗Use the autocollimator as the readout with a rotary stage, comparing face by face at 20±0.5 °C, three repeats per face.
Small Angles & Indexing Error↗References to check for selection, specifications and methods. Listing does not certify this model or prove testing to a standard; confirm the edition and applicable clauses in the technical agreement.
Conditional product-standard candidate, only for the relevant design; model applicability is unconfirmed.
Official directory ↗Application, geometrical specification or evaluation reference; not a claim of instrument conformity.
Official directory ↗Application, geometrical specification or evaluation reference; not a claim of instrument conformity.
Official directory ↗Application, geometrical specification or evaluation reference; not a claim of instrument conformity.
Official directory ↗Application, geometrical specification or evaluation reference; not a claim of instrument conformity.
Official directory ↗Application, geometrical specification or evaluation reference; not a claim of instrument conformity.
Official directory ↗Application, geometrical specification or evaluation reference; not a claim of instrument conformity.
Official directory ↗No directly applicable GB/ISO product standard was verified for this model. JB/T 9343-2024 is only a candidate if the design is an optical angle comparator.