Home / Regular polygon mirror method
ANGLE AND ALIGNMENT

Regular polygon mirror method

A polygon mirror with calibrated face angles plus an autocollimator gives full-circle indexing calibration.

Range0°–360°, 8/12/24/36 faces
Resolution0.1″ (with 0.1″ autocollimator)
Typical uncertainty0.3″–1″ (including polygon grade)

Principle

Face normals have calibrated angular spacing. Aligning each face in turn compares the table reading with the nominal angle; the closure error checks consistency.

Where it fits

Limits and risks

Related standards

Standard numbers for checking method clauses. Full texts are not redistributed; listing does not certify an instrument.

Related measurement tasks

Rotary Positioning & Reversal

Evaluate several rotary positions in both approach directions, separating position error, repeatability and reversal.

Our catalogue focuses on angular metrology; this technique is listed for method comparison and system planning.