MICROCRE / OPTICAL METROLOGY400-812-7833  ·  SHANGHAI
研润 WHW
MICROCREPRECISION IN EVERY ANGLE
Home / Model not specified by source · Catalogue no. YR-043 · Zhongji automatic-measurement autocollimator maximum measuring distance 20m
PRODUCT TECHNICAL SHEET

Model not specified by source · Catalogue no. YR-043 · Zhongji automatic-measurement autocollimator maximum measuring distance 20m

Zhongji automatic measurement series

Zhongji automatic-measurement autocollimator maximum measuring distance 20m accuracy 0.3
Catalogue no. YR-043

Zhongji automatic-measurement autocollimator maximum measuring distance 20m accuracy 0.3

Select using tolerance, distance, references and environmental conditions.

PDF for reading, editable Word; generated from the same source data.

Product overview

The MC030-ZJZD Zhongji automatic electronic autocollimator series integrates an automatic measurement module for tasks ranging from straightness inspection to rotary-table positioning accuracy. The source describes a workflow that can be operated by one person, simplifying measurement and supporting consistent automated results in production and research.

Applications

Machine tools: guideway straightness, parallelism and perpendicularity, and flatness of large surface plates. Optics: assembly, alignment and prism-angle measurement. Metrology and research: verification and calibration of measuring instruments and tools, precision angle measurement, dynamic monitoring of angular position, and angular or straightness-error measurement of moving products. Marble inspection: straightness, parallelism, perpendicularity and flatness. Encoders: angular-encoder positioning accuracy and repeatability.

Specifications

Objective focal length200mm
Clear aperture48mm
Maximum measuring distance20m
Field of view3200*2400″
Resolution0.01″ (adjustable)
Indication accuracy±100″ ±0.3″ ±1000″ ±1″
Light source typeImported high-power LED
CommunicationUSB2.0
Signal acquisitionHigh-precision photoelectric sensor
Display methodSoftware display on a standard PC
Instrument dimensions (L*W*H)290*135*125mm
Power supplyIntegrated power supply

Original source ↗ · 2026-11-14

Resolution is not accuracy. Preserve range conditions and confirm missing data with the engineering team.

MOTION DIAGRAM

How it works, animated

Four steps: where the light comes from, where it returns, how the reading appears.

Source / reticleObjective fPlane mirrorDetector: image shift → angle2θθ ≈ x / 2fSchematic · not to scale · not measured data
1 / 4
  1. Optical path: source collimated by the objective
  2. The mirror returns the beam along its own path
  3. The image point moves; the detector reads the shift
  4. Convert with θ = x/2f

The animation shows the optical path and how a reading arises. It does not represent the resolution, range or accuracy of this model.

Where this instrument is used

Product and measurement standards

References to check for selection, specifications and methods. Listing does not certify this model or prove testing to a standard; confirm the edition and applicable clauses in the technical agreement.

Product standard reference

JB/T 8232-2024 · Autocollimators

Product-standard candidate; confirm model applicability and inspection records. No conformity claim.

Official directory ↗
Application method reference

GB/T 17421.1-2023 · Machine tool testing — No-load or quasi-static geometry

Application, geometrical specification or evaluation reference; not a claim of instrument conformity.

Official directory ↗
Application method reference

GB/T 1958-2017 · GPS — Geometrical tolerance inspection and verification

Application, geometrical specification or evaluation reference; not a claim of instrument conformity.

Official directory ↗
Application method reference

GB/T 18779.1-2022 · GPS inspection — Conformity decision rules

Application, geometrical specification or evaluation reference; not a claim of instrument conformity.

Official directory ↗
Application method reference

ISO 230-1:2012 · Machine tools — Geometric accuracy under no-load or quasi-static conditions

Application, geometrical specification or evaluation reference; not a claim of instrument conformity.

Official directory ↗
Application method reference

ISO/TR 230-11:2018 · Measuring instruments for machine tool geometry tests

Instrument-selection technical report, not a manufacturing or product-certification standard.

Official directory ↗
Application method reference

ISO 12780-1:2011 · Straightness — Vocabulary and parameters

Application, geometrical specification or evaluation reference; not a claim of instrument conformity.

Official directory ↗
Application method reference

ISO 12781-1:2011 · Flatness — Vocabulary and parameters

Application, geometrical specification or evaluation reference; not a claim of instrument conformity.

Official directory ↗
Application method reference

ISO 14253-1:2017 · GPS — Conformity decision rules

Application, geometrical specification or evaluation reference; not a claim of instrument conformity.

Official directory ↗

GB/ISO entries mainly reference application methods. JB/T 8232-2024 is a product-standard candidate; model applicability and inspection records require confirmation. No conformity claim is made.