MICROCRE / OPTICAL METROLOGY400-812-7833  ·  SHANGHAI
研润 WHW
MICROCREPRECISION IN EVERY ANGLE
Home / Solutions
OPTICAL METROLOGY

Solutions

Define the method, reference and evaluation boundaries.

SOLUTIONS / 01

Guideway straightness inspection plan

For guideway assembly, adjustment and verification. Agree on the line, span, datum and evaluation method before reconstructing a profile from angular readings.

Read more ↗
SOLUTIONS / 02

Surface plate flatness inspection plan

For macroscopic plates, tables and mounting surfaces. Slope integration and direct height measurements require different data inputs.

Read more ↗
SOLUTIONS / 03

Machine axis squareness inspection plan

Evaluate the right-angle relation between mean motion-axis directions. Distinguish it from full-surface perpendicularity to a datum.

Read more ↗
SOLUTIONS / 04

Aerospace optomechanical assembly reference plan

For geometric checks of payload mounting references, precision fixtures and long guiding structures. This plan is not an airworthiness or structural certification.

Read more ↗
SOLUTIONS / 05

Optical assembly alignment and angle inspection plan

For directional adjustment of mirrors, optical platforms and optomechanical mounts. Establish a traceable direction before comparing relative angles.

Read more ↗
SOLUTIONS / 06

Optical metrology teaching and laboratory plan

Reproducible exercises for autocollimation, angular conversion, profile reconstruction and error evaluation. Keep example data separate from measured records.

Read more ↗
SOLUTIONS / 07

NC machine geometric acceptance (ISO 230-1)

For new-machine acceptance, post-relocation verification or overhaul. Measure each item with agreed lines, travel and evaluation.

Read more ↗
SOLUTIONS / 08

Linear axis positioning and repeatability (ISO 230-2)

Positioning, repeatability and reversal error of NC axes, precision stages and linear modules for acceptance, compensation and diagnosis.

Read more ↗
SOLUTIONS / 09

Rotary table and indexing head calibration

Full-circle indexing error and repeatability of NC tables, indexing heads and multi-tooth tables for acceptance, compensation and repair verification.

Read more ↗
SOLUTIONS / 10

Gantry dual-drive synchronisation and beam geometry

Combined check of synchronisation error, beam deflection and rail parallelism for large machine tools, cutters and additive systems.

Read more ↗
SOLUTIONS / 11

Granite plate grid flatness

Flatness of surface plates, machine tables and large bases, including grid design, closure checks and before/after lapping.

Read more ↗
SOLUTIONS / 12

Large slewing bearing and flange flatness

Flatness and parallelism of mounting faces on wind, construction and large rotary equipment.

Read more ↗
SOLUTIONS / 13

Telescope and multi-axis optical alignment

Alignment of primary and secondary mirrors, sensor boresights and laser transmit/receive paths.

Read more ↗
SOLUTIONS / 14

Wafer stage guideway and flatness

Straightness, flatness and thermal stability of wafer, exposure and precision XY stages.

Read more ↗
SOLUTIONS / 15

Robot cell installation and calibration

Base level, tool frame and relative pose of external axes or vision systems.

Read more ↗
SOLUTIONS / 16

Additive build platform and gantry accuracy

Substrate flatness, powder-bed plane and gantry motion directly affect layer thickness uniformity.

Read more ↗
SOLUTIONS / 17

Elevator and track guideway installation

Straightness, parallelism and joint step of elevator, machine and automation guideways for installation crews.

Read more ↗
SOLUTIONS / 18

Paper and film roll parallelism

Roll parallelism, elevation and level on paper, film and coating lines to reduce wrinkles and thickness variation.

Read more ↗
SOLUTIONS / 19

In-house angular calibration capability

Build internal calibration for autocollimators, electronic levels and angle standards, including equipment, environment and uncertainty budget.

Read more ↗
SOLUTIONS / 20

Aerospace tooling and section mating

Datum establishment, mating alignment and contour checks for aircraft sections, wing fixtures and final assembly tooling.

Read more ↗
SOLUTIONS / 21

Flatness inspection plan for a surface grinder table

For installation acceptance and periodic re-inspection of a rectangular surface grinder table (800×400 mm, example/teaching data). An autocollimator measures the straightness of grid lines; heights are tied to a common datum through shared intersection nodes to build a full-surface height matrix. The evaluation method (minimum zone or least squares) must be agreed before measurement and the two results must never share the same name. Sequence: agree datum and method, lay out stations and measure, convert and evaluate, then run a reverse check and deliver records.

Read more ↗
SOLUTIONS / 22

Verification plan for a CMM granite table

For periodic verification and post-repair re-checks of a CMM granite table (1000×800 mm, example/teaching data). Autocollimator diagonal and grid lines are primary; an electronic level cross-checks shared lines. Confirm the support state and evaluation datum first, then measure, unify the datum and evaluate, run a reverse check and deliver verification records.

Read more ↗
SOLUTIONS / 23

Geometric inspection plan for gantry mill crossbeam guideways

For the vertical/horizontal straightness and mutual parallelism of the two guideways of a gantry mill crossbeam (4000 mm useful travel, example/teaching data). The long travel is measured in segments with overlapping splices and merged into one profile. Agree support and ram position first, then acquire segments, register splices, reverse-repeat and deliver records.

Read more ↗
SOLUTIONS / 24

Level and face inspection plan for a vertical lathe table

For the installation level and face flatness of a vertical lathe circular table (Ø1600 mm, example/teaching data). The autocollimator measures radial generatrices through the centre; an electronic level cross-checks the overall tilt in two orthogonal directions. Lines are tied to a common datum at the centre to evaluate flatness and derive the levelling correction.

Read more ↗
SOLUTIONS / 25

Alignment inspection plan for a boring headstock vertical traverse

For the alignment of a floor/horizontal boring machine headstock traversing the column (1500 mm travel, example/teaching data) relative to the spindle axis. A test mandrel with an end-face mirror establishes the spindle axis datum; the autocollimator reads two-axis angular deviation over the full traverse, which is integrated into an axis-offset curve. Bidirectional measurement with averaging separates stick-slip and backlash effects.

Read more ↗
SOLUTIONS / 26

Installation inspection plan for a cleanroom precision motion stage

For post-installation inspection of an air-bearing/linear-motor precision stage in a cleanroom (600×600 mm base, example/teaching data): base flatness, overall level and in-travel attitude angles (pitch/yaw/roll). Clean, ESD-safe operation throughout, with micro-vibration and thermal disturbance controlled. Agree the datum, grid-measure the base, step through travel for attitude angles, then re-measure after settling.

Read more ↗
SOLUTIONS / 27

Flatness inspection plan for photovoltaic module frames

For sampling inspection of PV aluminium frame flatness (2278×1134 mm, example/teaching data) before and after lamination. The frame is flexible, so results depend strongly on the support state, which must be fixed in the plan. An autocollimator profiles the mid-surface of the long side; evaluation uses the endpoint-line datum with a flipped re-measurement.

Read more ↗
SOLUTIONS / 28

Coaxiality and level inspection plan for wind turbine mainshaft bearing seats

For coaxiality and installation level of the front and rear mainshaft bearing seats on a wind turbine bedplate (3500 mm centre distance, example/teaching data). The autocollimator establishes a reference optical axis; an adjustable target mirror reads lateral offset and tilt at each seat, and an electronic level checks the mounting faces. Four rotational target orientations cancel target eccentricity; keep before/after adjustment data sets.

Read more ↗
SOLUTIONS / 29

Guide attitude-angle inspection plan for a mechanical press slide

For pitch/yaw measurement over the full stroke of a mechanical press slide (300 mm stroke, example/teaching data), used to assess guide clearance uniformity and gib parallelism. The mirror is rigidly mounted on the slide; the autocollimator on a stable press-frame stand reads station by station, with bidirectional averaging.

Read more ↗
SOLUTIONS / 30

Parallelism inspection plan for injection moulding machine platens

For parallelism of the fixed and moving platens of an injection moulding machine in the clamped state (900×900 mm clamping face, example/teaching data). In the open state, measure each platen face flatness on a grid; under low-pressure clamping, evaluate parallelism from the four-corner gap difference. Fix the clamping force level and repeat clamping three times.

Read more ↗
SOLUTIONS / 31

Perpendicularity inspection plan for a rolling mill housing window

For perpendicularity of the two column faces of a rolling mill housing window (4000 mm window height, example/teaching data) to its base, and the relative angle (gap taper) between the column faces. A pentaprism folds the vertical measuring line into the horizontal autocollimator path; the base reference line is measured first, then the column face station by station.

Read more ↗
SOLUTIONS / 32

Bed guideway inspection plan for a CNC lathe

For straightness in the vertical and horizontal planes and twist of the two guideways of a CNC lathe bed (2000 mm long, example/teaching data). The dual-axis autocollimator reads the main guideway; a bridge spanning both guideways reads roll. Level the bed and record the wedge state first, then measure, convert and reverse-repeat.

Read more ↗
SOLUTIONS / 33

Splice flatness inspection plan for optical breadboards

For splice flatness and seam steps after joining multiple optical breadboards into one surface (2×1 pieces of 600×900 mm, example/teaching data). Support per the vendor's recommended array, measure the full surface on a grid, evaluate against a least-squares reference and report seam steps separately.

Read more ↗
SOLUTIONS / 34

Inspection plan for theodolite sighting axis versus trunnion axis

For laboratory determination of a theodolite/total station sighting-axis error (collimation c) and trunnion-axis tilt error (i). The autocollimator in collimating mode provides an infinity reference target; face-left/face-right observations separate collimation, and targets at high and low elevations separate trunnion tilt.

Read more ↗
SOLUTIONS / 35

Assembly flatness inspection plan for a satellite panel

For assembly-state flatness of a satellite honeycomb panel (2000×1500 mm, example/teaching data). Emphasis on low-stress fixturing, temperature stability criteria and drift monitoring throughout. The full surface is measured on a grid with a closed-loop drift monitor; data exceeding the drift criterion are discarded and re-measured.

Read more ↗
SOLUTIONS / 36

Levelling inspection plan for a hydro turbine stay-ring flange

For installation level and face flatness of a hydro turbine stay-ring flange (Ø6000 mm, example/teaching data). The autocollimator measures multiple radial lines on the large-diameter face, tied to a common datum at the centre; an electronic level cross-checks overall tilt on two orthogonal diameters. After adjustment, re-measure the full ring and keep both versions.

Read more ↗
SOLUTIONS / 37

Geometry inspection plan for a railway bogie frame

For straightness of the two side beams, their mutual parallelism and the rectangularity of a railway bogie frame (2500 mm wheelbase, example/teaching data). The autocollimator establishes a reference axis on one side beam; a datum-transfer target carries it to the opposite beam, and diagonal lengths are checked with length gauges.

Read more ↗
SOLUTIONS / 38

Installation verticality inspection plan for elevator guide rails

For installation verticality of elevator T-rails (60 m shaft, example/teaching data) and sampling of joint steps. The autocollimator establishes the reference path from the pit, each rail section is measured in angle and compared with the shaft plumb reference, with densified stations at joints.

Read more ↗
SOLUTIONS / 39

Camber inspection plan for an overhead crane main girder

For no-load camber of an overhead crane main girder (22.5 m span, example/teaching data) with a loaded-deflection comparison. With the support and trolley position fixed, the autocollimator profiles the centreline of the top cover plate; camber is evaluated against the endpoint line and re-measured under load for comparison.

Read more ↗
SOLUTIONS / 40

Bed guideway inspection plan for a roll grinder

For straightness and twist of the extra-long guideways of a roll grinder bed (12000 mm, example/teaching data). Multi-segment spliced measurement is used; the first station of each segment is re-read to monitor drift, with the temperature field and instrument relocation error tightly controlled.

Read more ↗