28 engineering walkthroughs plus industry and method cases, each stating conditions, readings, calculation and limits.
Conditions, readings, calculation, verdict
Each case carries a full data chain you can adapt to your own conditions.
Straightness of a 12 m gantry beam: rebuilding a profile from segment angles
Beam sag changes tool height along the travel. A long-range autocollimator reads the angle segment by segment at a 500 mm span, and accumulating those angles gives the height profile.
900 mm granite plate: 3×3 grid flatness
A single line cannot describe flatness. A 3×3 grid over the working surface, with each line integrated into station heights and evaluated against one common datum, gives a reproducible flatness value.
Two-section alignment: separating offset from tilt
One section only tells you how far the spot is offset, not whether the cause is translation or tilt. Two sections at a known separation separate the two.
Rotary table indexing error: 12-position closure test
Indexing error is not a single-point error but a sequence of deviations from nominal angles. An autocollimator with an angle reference reads each position, and a return-to-zero check shows whether the data are trustworthy.
Squareness of a 3 m column: two-section method with a pentaprism
A leaning column shifts the spindle position along its height. A pentaprism folds the beam through 90°; angles read at eleven heights accumulate into the generatrix offset curve, then convert to μm/m.
1500×1000 granite plate: a 9×7 grid and two lapping passes
Out-of-flatness on a large plate usually concentrates at a few high points. A 9×7 grid locates them, a planned lapping path removes them, and a re-measure confirms convergence.
200 mm precision stage: separating accumulation from reversal jump
Unidirectional pitch accumulation is often modest; what hurts bidirectional positioning is the jump at reversal. Separate the two sampling modes to tell geometry from preload.
12″ of secondary tilt in an f/10 telescope: from angle to focus shift
Arcseconds of secondary tilt look small, but at 4 m focal length they become hundreds of microns of focus shift. Measuring tilt and converting through focal length is the shortest route to a decision.
Cold alignment of an 8 m shaft line: two sections turn angle into offset
A single section cannot separate shaft tilt from target eccentricity. Reading at two sections 2 m apart gives the tilt directly, which then converts to coupling-face offset.
400 mm parting-line parallelism: judging margin behind 4.1″
Parting-line parallelism is usually quoted in millimetres, but what you measure is an angle. Converting 0.008 mm over 400 mm to 4.1″ shows how much margin is left.
12-position rotary table: 3.5″ peak-to-valley and a reversal table
Indexing error is not random noise; it repeats with angular position. A 12-position deviation curve both judges acceptance and generates the compensation table.
1.2 m AM gantry: how 7 μm of undulation eats layer margin
Layer thickness is only 20–60 μm, so gantry undulation along travel becomes thickness variation. Over 1.2 m, 7 μm peak-to-valley already consumes a third of a 20 μm layer.
Encoder positioning accuracy: polygon and autocollimator comparison
High-grade encoder positioning error must be compared against a mechanical angle standard. Mount a 23-face polygon on the encoder shaft, read face angles with an autocollimator, and compare point by point with the encoder output to obtain the full-revolution error curve.
Robot base installation: reading pitch and roll simultaneously
Base levelness of a six-axis robot directly affects absolute accuracy. A dual-axis autocollimator reads both directions at once, far faster than moving a level back and forth, and misses nothing when adjustments interact.
Semiconductor stage guideways: evaluating straightness in two planes
Vertical-plane straightness of a wafer stage guideway affects the focal plane; horizontal-plane straightness affects overlay. Measure and evaluate the two planes separately — never merge them into one "total straightness".
Microscope stage Z axis: straightness of the focusing motion
If the Z focusing motion is not straight, slide scanning and stitching show lateral jumps. Fix a small mirror on the stage, read the angular change over the travel with an autocollimator, and convert to lateral offset.
Teaching lab on prism angles: from setup to uncertainty
Prism angle measurement is the classic entry lab of angle metrology: aim the autocollimator at the two working faces in turn, and the difference of the two readings is the dihedral angle. The lab trains datum selection, repeatability statistics and uncertainty budgeting.
Beam-path coaxial alignment after laser cutting head replacement
After replacing a cutting head, beam-to-nozzle coaxiality directly affects kerf quality. An autocollimator with a reflective target turns the invisible beam path into a readable angle.
Eight-metre gantry: splitting synchronisation error into geometry and control
A dual-drive gantry that passes at low speed but fails at high speed usually has mismatched servo response, not bad rails. Rule out geometry statically, then acquire both sides synchronously.
Indexing table, both directions: how much of 3.5″ is backlash
A unidirectional test folds backlash into indexing accuracy. Measuring both directions shows whether to compensate or repair.
1.2 m plate grid: what a 4 μm closure means
Closure is the cheapest self-check in grid flatness: it does not prove the form, but it does show whether the run is trustworthy.
Robot cell: 0.3° base tilt becomes 2 mm at reach
Base level is often treated as approximate. Over a 1.5 m reach, 0.3° is 7.8 mm at the tool; level first, then calibrate.
Yaw bearing housing: separating offset from tilt with two sections
If the two mounting faces of a yaw bearing housing are not coaxial, the gear mesh is periodically overloaded. Two target sections in one set-up give both offset and tilt.
Bogie brake disc parallelism: turning 6.2″ into 0.036 mm
Non-parallel brake disc faces cause uneven wear and vibration. The angle between two stations converts to a face height difference over the disc diameter.
Printing press roller parallelism: the geometry behind register error
Register errors are often blamed on tension control, yet non-parallel roller axes shift the image linearly across the web. Measure parallelism first.
Glass annealing lehr rollers: six stations, 0.004 mm closure
Uneven lehr rollers imprint periodic waves on the glass ribbon. Accumulating station angles gives a height profile and identifies the rollers to adjust.
CMM MPE acceptance: judging five lengths
The ISO 10360-2 MPE limit varies with length. Five measured lengths compared with the formula show whether the machine is still in acceptance state.
Turbine blade setting angle: twist from four corners
Setting-angle error changes the flow area and efficiency. Four corner readings give a twist figure that describes the whole blade, not one point.
Index by industry and method
Teaching example: reconstructing a machine-tool guideway
Machine Tools
Read more ↗INDUSTRY CASEClosed datum transfer on a large aerospace assembly fixture
Aerospace
Read more ↗INDUSTRY CASETeaching lab: resolution, repeatability and uncertainty of the mean
Education
Read more ↗INDUSTRY CASEOptomechanical assembly: separate decentring from tilt using two planes
Optics & Optomechanics
Read more ↗INDUSTRY CASESemiconductor stage: angular change and Abbe-arm effects
Semiconductor Equipment
Read more ↗INDUSTRY CASEAutomotive fixture: converting a right-angle direction error to a length effect
Automotive & New Energy
Read more ↗INDUSTRY CASERail and energy equipment: directional parallelism of two installation guides
Rail & Energy Equipment
Read more ↗INDUSTRY CASEMetrology laboratory: a simplified angle-comparison uncertainty budget
Metrology & R&D
Read more ↗INDUSTRY CASEAutomation external linear axis: repeat arrivals at one station
Robotics & Automated Assembly
Read more ↗INDUSTRY CASETeaching check of recoater-guide angular change
Additive Manufacturing & Laser Processing
Read more ↗INDUSTRY CASENine-point mould-base grid and assembly-datum tutorial
Precision Moulds & Tooling
Read more ↗INDUSTRY CASEReproducing granite-base support after repositioning
Granite & Precision Bases
Read more ↗INDUSTRY CASEThree-stage guideway comparison before repair, after adjustment and after locking
Machine Rebuild & Maintenance
Read more ↗INDUSTRY CASETeaching remounting study for an imaging-equipment component seat
Medical Equipment Assembly
Read more ↗INDUSTRY CASEDisplay-substrate stage direction before and after vacuum loading
Display & Electronics Manufacturing
Read more ↗INDUSTRY CASESegmented closure check for marine-equipment installation datums
Shipbuilding & Marine Equipment
Read more ↗INDUSTRY CASEHalf-hour stability observation of a telescope mirror mount
Astronomy & Large Optical Systems
Read more ↗INDUSTRY CASETeaching height-datum stitching between overlapping beamline-support stations
Research Facilities & Beamline Assembly
Read more ↗INDUSTRY CASEGeometric control path on a battery-module line
New energy and battery manufacturing
Read more ↗INDUSTRY CASEGeometric inspection path for rail vehicles and bogies
Rail transit and rolling stock
Read more ↗INDUSTRY CASELarge-scale geometric inspection for power equipment
Power generation equipment
Read more ↗INDUSTRY CASERoll and register accuracy on printing and packaging machines
Printing and packaging
Read more ↗INDUSTRY CASEFlatness and angle inspection for glass and technical ceramics
Glass and technical ceramics
Read more ↗INDUSTRY CASEBuilding capability in a testing or calibration laboratory
Testing and calibration laboratories
Read more ↗METHOD CASEStraightness
Illustration: L=100 mm and θ=1″ give about 0.4848 μm over one interval, not the straightness of the entire gui
Read more ↗METHOD CASEFlatness
Illustration: fitted residuals of +2 and −1 μm give a 3 μm PV about that plane, not automatically minimum-zone
Read more ↗METHOD CASEPerpendicularity & Squareness
Illustration: 2″ over 500 mm corresponds to about 4.85 μm of directional tilt, excluding surface form.
Read more ↗METHOD CASEParallelism
Illustration: directions differing by 1″ in a shared reference correspond to about 0.97 μm over 200 mm.
Read more ↗METHOD CASESmall Angles & Indexing Error
Illustration: a corrected position of 10°+0.4″ has a +0.4″ error relative to nominal 10°.
Read more ↗METHOD CASEOptical Alignment
Illustration: a 10 μm offset difference over 1 m gives about 10 μrad or 2.06″; overall decentring remains sepa
Read more ↗METHOD CASEStage Pitch & Yaw
Illustration: 0.8″ forward and 0.5″ reverse at one station differ by 0.3″; this is not a complete positioning-
Read more ↗METHOD CASERotary Positioning & Reversal
Illustration: mean deviations +0.6″ forward and +0.2″ reverse give +0.4″ directional difference.
Read more ↗METHOD CASEPrism & Polygon Angle Comparison
Illustration: in that geometry, a normal rotation of 90°+1″ corresponds to an internal angle of 90°−1″.
Read more ↗METHOD CASEThermal Drift & Stability
Illustration: a change from 0.1″ to 0.4″ in one hour gives a 0.3″ endpoint change; two points do not prove lin
Read more ↗METHOD CASERepeatability & Re-setup Verification
Illustration: for ten independent readings with s=0.20″, uA of the mean is about 0.063″, excluding calibration
Read more ↗METHOD CASEMeasurement Uncertainty Budget
Illustration: independent standard uncertainties of 0.10″ and 0.05″ give uc≈0.112″. If k=2 is justified, U≈0.2
Read more ↗METHOD CASEGuideway Adjustment & Verification
Illustration: a point changing from +4 to +1 μm in the same reference changes by −3 μm; other stations and the
Read more ↗METHOD CASEDatum Transfer & Closure Checks
Illustration: increments +2, +3, −1 and −3 μm give +1 μm closure. Investigate its cause rather than declaring
Read more ↗METHOD CASEGuideway twist and rail height difference
Example: 8″ over a 300 mm span gives about 11.6 μm height difference; 2″ repeatability gives about 3 μm uncert
Read more ↗METHOD CASELevelling and datum establishment
Example: 0.02 mm/m and 0.01 mm/m correspond to about 4.1″ and 2.1″, or 40 μm and 20 μm over 2 m.
Read more ↗METHOD CASECoaxiality and runout by two sections
Example: e = 5 and 15 μm over 400 mm gives about 5″ tilt and 30 μm diameter coaxiality.
Read more ↗METHOD CASERoundness and cylindricity
Example: 3.2 μm in one section with 2 μm centre offset gives cylindricity larger than any single roundness val
Read more ↗METHOD CASEVolumetric diagonal test
Example: maxima of 18 and 6 μm across diagonals indicate a directional term to investigate.
Read more ↗METHOD CASELong-term monitoring and trending
Example: baseline 4.2″ with σ = 0.6″; five points above 5.4″ indicate a systematic shift.
Read more ↗PLANGuideway straightness inspection plan
For guideway assembly, adjustment and verification. Agree on the line, span, datum and evaluation method before reconstructing a profile from angular readings.
Read more ↗PLANSurface plate flatness inspection plan
For macroscopic plates, tables and mounting surfaces. Slope integration and direct height measurements require different data inputs.
Read more ↗PLANMachine axis squareness inspection plan
Evaluate the right-angle relation between mean motion-axis directions. Distinguish it from full-surface perpendicularity to a datum.
Read more ↗PLANAerospace optomechanical assembly reference plan
For geometric checks of payload mounting references, precision fixtures and long guiding structures. This plan is not an airworthiness or structural certification.
Read more ↗PLANOptical assembly alignment and angle inspection plan
For directional adjustment of mirrors, optical platforms and optomechanical mounts. Establish a traceable direction before comparing relative angles.
Read more ↗PLANOptical metrology teaching and laboratory plan
Reproducible exercises for autocollimation, angular conversion, profile reconstruction and error evaluation. Keep example data separate from measured records.
Read more ↗PLANNC machine geometric acceptance (ISO 230-1)
For new-machine acceptance, post-relocation verification or overhaul. Measure each item with agreed lines, travel and evaluation.
Read more ↗PLANLinear axis positioning and repeatability (ISO 230-2)
Positioning, repeatability and reversal error of NC axes, precision stages and linear modules for acceptance, compensation and diagnosis.
Read more ↗PLANRotary table and indexing head calibration
Full-circle indexing error and repeatability of NC tables, indexing heads and multi-tooth tables for acceptance, compensation and repair verification.
Read more ↗PLANGantry dual-drive synchronisation and beam geometry
Combined check of synchronisation error, beam deflection and rail parallelism for large machine tools, cutters and additive systems.
Read more ↗PLANGranite plate grid flatness
Flatness of surface plates, machine tables and large bases, including grid design, closure checks and before/after lapping.
Read more ↗PLANLarge slewing bearing and flange flatness
Flatness and parallelism of mounting faces on wind, construction and large rotary equipment.
Read more ↗PLANTelescope and multi-axis optical alignment
Alignment of primary and secondary mirrors, sensor boresights and laser transmit/receive paths.
Read more ↗PLANWafer stage guideway and flatness
Straightness, flatness and thermal stability of wafer, exposure and precision XY stages.
Read more ↗PLANRobot cell installation and calibration
Base level, tool frame and relative pose of external axes or vision systems.
Read more ↗PLANAdditive build platform and gantry accuracy
Substrate flatness, powder-bed plane and gantry motion directly affect layer thickness uniformity.
Read more ↗PLANElevator and track guideway installation
Straightness, parallelism and joint step of elevator, machine and automation guideways for installation crews.
Read more ↗PLANPaper and film roll parallelism
Roll parallelism, elevation and level on paper, film and coating lines to reduce wrinkles and thickness variation.
Read more ↗PLANIn-house angular calibration capability
Build internal calibration for autocollimators, electronic levels and angle standards, including equipment, environment and uncertainty budget.
Read more ↗PLANAerospace tooling and section mating
Datum establishment, mating alignment and contour checks for aircraft sections, wing fixtures and final assembly tooling.
Read more ↗Every case is marked as a teaching demonstration or method illustration. Data are assumed to explain the calculation and do not represent a customer project or acceptance result.