MICROCRE / OPTICAL METROLOGY400-812-7833  ·  SHANGHAI
研润 WHW
MICROCREPRECISION IN EVERY ANGLE
Home / Cases
CASE LIBRARY · 28 WALKTHROUGHS

Cases

28 engineering walkthroughs plus industry and method cases, each stating conditions, readings, calculation and limits.

ENGINEERING WALKTHROUGHS

Conditions, readings, calculation, verdict

Each case carries a full data chain you can adapt to your own conditions.

01
Machine Tools

Straightness of a 12 m gantry beam: rebuilding a profile from segment angles

Beam sag changes tool height along the travel. A long-range autocollimator reads the angle segment by segment at a 500 mm span, and accumulating those angles gives the height profile.

Straightness4 sectionsteaching data
02
Granite & Precision Bases

900 mm granite plate: 3×3 grid flatness

A single line cannot describe flatness. A 3×3 grid over the working surface, with each line integrated into station heights and evaluated against one common datum, gives a reproducible flatness value.

Flatness4 sectionsteaching data
03
Optics & Optomechanics

Two-section alignment: separating offset from tilt

One section only tells you how far the spot is offset, not whether the cause is translation or tilt. Two sections at a known separation separate the two.

Optical Alignment4 sectionsteaching data
04
Metrology & R&D

Rotary table indexing error: 12-position closure test

Indexing error is not a single-point error but a sequence of deviations from nominal angles. An autocollimator with an angle reference reads each position, and a return-to-zero check shows whether the data are trustworthy.

Rotary Positioning & Reversal4 sectionsteaching data
05
Machine Tools

Squareness of a 3 m column: two-section method with a pentaprism

A leaning column shifts the spindle position along its height. A pentaprism folds the beam through 90°; angles read at eleven heights accumulate into the generatrix offset curve, then convert to μm/m.

Perpendicularity & Squareness3 sectionsteaching data
06
Granite & Precision Bases

1500×1000 granite plate: a 9×7 grid and two lapping passes

Out-of-flatness on a large plate usually concentrates at a few high points. A 9×7 grid locates them, a planned lapping path removes them, and a re-measure confirms convergence.

Flatness3 sectionsteaching data
07
Semiconductor Equipment

200 mm precision stage: separating accumulation from reversal jump

Unidirectional pitch accumulation is often modest; what hurts bidirectional positioning is the jump at reversal. Separate the two sampling modes to tell geometry from preload.

Stage Pitch & Yaw3 sectionsteaching data
08
Astronomy & Large Optical Systems

12″ of secondary tilt in an f/10 telescope: from angle to focus shift

Arcseconds of secondary tilt look small, but at 4 m focal length they become hundreds of microns of focus shift. Measuring tilt and converting through focal length is the shortest route to a decision.

Small Angles & Indexing Error3 sectionsteaching data
09
Shipbuilding & Marine Equipment

Cold alignment of an 8 m shaft line: two sections turn angle into offset

A single section cannot separate shaft tilt from target eccentricity. Reading at two sections 2 m apart gives the tilt directly, which then converts to coupling-face offset.

Optical Alignment3 sectionsteaching data
10
Precision Moulds & Tooling

400 mm parting-line parallelism: judging margin behind 4.1″

Parting-line parallelism is usually quoted in millimetres, but what you measure is an angle. Converting 0.008 mm over 400 mm to 4.1″ shows how much margin is left.

Parallelism3 sectionsteaching data
11
Metrology & R&D

12-position rotary table: 3.5″ peak-to-valley and a reversal table

Indexing error is not random noise; it repeats with angular position. A 12-position deviation curve both judges acceptance and generates the compensation table.

Rotary Positioning & Reversal3 sectionsteaching data
12
Additive Manufacturing & Laser Processing

1.2 m AM gantry: how 7 μm of undulation eats layer margin

Layer thickness is only 20–60 μm, so gantry undulation along travel becomes thickness variation. Over 1.2 m, 7 μm peak-to-valley already consumes a third of a 20 μm layer.

Straightness3 sectionsteaching data
13
Metrology & R&D

Encoder positioning accuracy: polygon and autocollimator comparison

High-grade encoder positioning error must be compared against a mechanical angle standard. Mount a 23-face polygon on the encoder shaft, read face angles with an autocollimator, and compare point by point with the encoder output to obtain the full-revolution error curve.

Repeatability & Re-setup Verification4 sectionsteaching data
14
Robotics & Automated Assembly

Robot base installation: reading pitch and roll simultaneously

Base levelness of a six-axis robot directly affects absolute accuracy. A dual-axis autocollimator reads both directions at once, far faster than moving a level back and forth, and misses nothing when adjustments interact.

Stage Pitch & Yaw3 sectionsteaching data
15
Semiconductor Equipment

Semiconductor stage guideways: evaluating straightness in two planes

Vertical-plane straightness of a wafer stage guideway affects the focal plane; horizontal-plane straightness affects overlay. Measure and evaluate the two planes separately — never merge them into one "total straightness".

Straightness3 sectionsteaching data
16
Medical Equipment Assembly

Microscope stage Z axis: straightness of the focusing motion

If the Z focusing motion is not straight, slide scanning and stitching show lateral jumps. Fix a small mirror on the stage, read the angular change over the travel with an autocollimator, and convert to lateral offset.

Straightness3 sectionsteaching data
17
Education

Teaching lab on prism angles: from setup to uncertainty

Prism angle measurement is the classic entry lab of angle metrology: aim the autocollimator at the two working faces in turn, and the difference of the two readings is the dihedral angle. The lab trains datum selection, repeatability statistics and uncertainty budgeting.

Prism & Polygon Angle Comparison3 sectionsteaching data
18
Rail & Energy Equipment

Beam-path coaxial alignment after laser cutting head replacement

After replacing a cutting head, beam-to-nozzle coaxiality directly affects kerf quality. An autocollimator with a reflective target turns the invisible beam path into a readable angle.

Optical Alignment3 sectionsteaching data
19
Rail & Energy Equipment

Eight-metre gantry: splitting synchronisation error into geometry and control

A dual-drive gantry that passes at low speed but fails at high speed usually has mismatched servo response, not bad rails. Rule out geometry statically, then acquire both sides synchronously.

Repeatability & Re-setup Verification3 sectionsteaching data
20
Machine Tools

Indexing table, both directions: how much of 3.5″ is backlash

A unidirectional test folds backlash into indexing accuracy. Measuring both directions shows whether to compensate or repair.

Rotary Positioning & Reversal3 sectionsteaching data
21
Granite & Precision Bases

1.2 m plate grid: what a 4 μm closure means

Closure is the cheapest self-check in grid flatness: it does not prove the form, but it does show whether the run is trustworthy.

Flatness2 sectionsteaching data
22
Robotics & Automated Assembly

Robot cell: 0.3° base tilt becomes 2 mm at reach

Base level is often treated as approximate. Over a 1.5 m reach, 0.3° is 7.8 mm at the tool; level first, then calibrate.

Optical Alignment2 sectionsteaching data
23
New energy and battery manufacturing

Yaw bearing housing: separating offset from tilt with two sections

If the two mounting faces of a yaw bearing housing are not coaxial, the gear mesh is periodically overloaded. Two target sections in one set-up give both offset and tilt.

Coaxiality and runout by two sections3 sectionsteaching data
24
Rail transit and rolling stock

Bogie brake disc parallelism: turning 6.2″ into 0.036 mm

Non-parallel brake disc faces cause uneven wear and vibration. The angle between two stations converts to a face height difference over the disc diameter.

Parallelism3 sectionsteaching data
25
Printing and packaging

Printing press roller parallelism: the geometry behind register error

Register errors are often blamed on tension control, yet non-parallel roller axes shift the image linearly across the web. Measure parallelism first.

Parallelism3 sectionsteaching data
26
Glass and technical ceramics

Glass annealing lehr rollers: six stations, 0.004 mm closure

Uneven lehr rollers imprint periodic waves on the glass ribbon. Accumulating station angles gives a height profile and identifies the rollers to adjust.

Levelling and datum establishment3 sectionsteaching data
27
Testing and calibration laboratories

CMM MPE acceptance: judging five lengths

The ISO 10360-2 MPE limit varies with length. Five measured lengths compared with the formula show whether the machine is still in acceptance state.

Volumetric diagonal test3 sectionsteaching data
28
Power generation equipment

Turbine blade setting angle: twist from four corners

Setting-angle error changes the flow area and efficiency. Four corner readings give a twist figure that describes the whole blade, not one point.

Guideway twist and rail height difference3 sectionsteaching data

Index by industry and method

INDUSTRY CASE

Teaching example: reconstructing a machine-tool guideway

Machine Tools

Read more ↗
INDUSTRY CASE

Closed datum transfer on a large aerospace assembly fixture

Aerospace

Read more ↗
INDUSTRY CASE

Teaching lab: resolution, repeatability and uncertainty of the mean

Education

Read more ↗
INDUSTRY CASE

Optomechanical assembly: separate decentring from tilt using two planes

Optics & Optomechanics

Read more ↗
INDUSTRY CASE

Semiconductor stage: angular change and Abbe-arm effects

Semiconductor Equipment

Read more ↗
INDUSTRY CASE

Automotive fixture: converting a right-angle direction error to a length effect

Automotive & New Energy

Read more ↗
INDUSTRY CASE

Rail and energy equipment: directional parallelism of two installation guides

Rail & Energy Equipment

Read more ↗
INDUSTRY CASE

Metrology laboratory: a simplified angle-comparison uncertainty budget

Metrology & R&D

Read more ↗
INDUSTRY CASE

Automation external linear axis: repeat arrivals at one station

Robotics & Automated Assembly

Read more ↗
INDUSTRY CASE

Teaching check of recoater-guide angular change

Additive Manufacturing & Laser Processing

Read more ↗
INDUSTRY CASE

Nine-point mould-base grid and assembly-datum tutorial

Precision Moulds & Tooling

Read more ↗
INDUSTRY CASE

Reproducing granite-base support after repositioning

Granite & Precision Bases

Read more ↗
INDUSTRY CASE

Three-stage guideway comparison before repair, after adjustment and after locking

Machine Rebuild & Maintenance

Read more ↗
INDUSTRY CASE

Teaching remounting study for an imaging-equipment component seat

Medical Equipment Assembly

Read more ↗
INDUSTRY CASE

Display-substrate stage direction before and after vacuum loading

Display & Electronics Manufacturing

Read more ↗
INDUSTRY CASE

Segmented closure check for marine-equipment installation datums

Shipbuilding & Marine Equipment

Read more ↗
INDUSTRY CASE

Half-hour stability observation of a telescope mirror mount

Astronomy & Large Optical Systems

Read more ↗
INDUSTRY CASE

Teaching height-datum stitching between overlapping beamline-support stations

Research Facilities & Beamline Assembly

Read more ↗
INDUSTRY CASE

Geometric control path on a battery-module line

New energy and battery manufacturing

Read more ↗
INDUSTRY CASE

Geometric inspection path for rail vehicles and bogies

Rail transit and rolling stock

Read more ↗
INDUSTRY CASE

Large-scale geometric inspection for power equipment

Power generation equipment

Read more ↗
INDUSTRY CASE

Roll and register accuracy on printing and packaging machines

Printing and packaging

Read more ↗
INDUSTRY CASE

Flatness and angle inspection for glass and technical ceramics

Glass and technical ceramics

Read more ↗
INDUSTRY CASE

Building capability in a testing or calibration laboratory

Testing and calibration laboratories

Read more ↗
METHOD CASE

Straightness

Illustration: L=100 mm and θ=1″ give about 0.4848 μm over one interval, not the straightness of the entire gui

Read more ↗
METHOD CASE

Flatness

Illustration: fitted residuals of +2 and −1 μm give a 3 μm PV about that plane, not automatically minimum-zone

Read more ↗
METHOD CASE

Perpendicularity & Squareness

Illustration: 2″ over 500 mm corresponds to about 4.85 μm of directional tilt, excluding surface form.

Read more ↗
METHOD CASE

Parallelism

Illustration: directions differing by 1″ in a shared reference correspond to about 0.97 μm over 200 mm.

Read more ↗
METHOD CASE

Small Angles & Indexing Error

Illustration: a corrected position of 10°+0.4″ has a +0.4″ error relative to nominal 10°.

Read more ↗
METHOD CASE

Optical Alignment

Illustration: a 10 μm offset difference over 1 m gives about 10 μrad or 2.06″; overall decentring remains sepa

Read more ↗
METHOD CASE

Stage Pitch & Yaw

Illustration: 0.8″ forward and 0.5″ reverse at one station differ by 0.3″; this is not a complete positioning-

Read more ↗
METHOD CASE

Rotary Positioning & Reversal

Illustration: mean deviations +0.6″ forward and +0.2″ reverse give +0.4″ directional difference.

Read more ↗
METHOD CASE

Prism & Polygon Angle Comparison

Illustration: in that geometry, a normal rotation of 90°+1″ corresponds to an internal angle of 90°−1″.

Read more ↗
METHOD CASE

Thermal Drift & Stability

Illustration: a change from 0.1″ to 0.4″ in one hour gives a 0.3″ endpoint change; two points do not prove lin

Read more ↗
METHOD CASE

Repeatability & Re-setup Verification

Illustration: for ten independent readings with s=0.20″, uA of the mean is about 0.063″, excluding calibration

Read more ↗
METHOD CASE

Measurement Uncertainty Budget

Illustration: independent standard uncertainties of 0.10″ and 0.05″ give uc≈0.112″. If k=2 is justified, U≈0.2

Read more ↗
METHOD CASE

Guideway Adjustment & Verification

Illustration: a point changing from +4 to +1 μm in the same reference changes by −3 μm; other stations and the

Read more ↗
METHOD CASE

Datum Transfer & Closure Checks

Illustration: increments +2, +3, −1 and −3 μm give +1 μm closure. Investigate its cause rather than declaring

Read more ↗
METHOD CASE

Guideway twist and rail height difference

Example: 8″ over a 300 mm span gives about 11.6 μm height difference; 2″ repeatability gives about 3 μm uncert

Read more ↗
METHOD CASE

Levelling and datum establishment

Example: 0.02 mm/m and 0.01 mm/m correspond to about 4.1″ and 2.1″, or 40 μm and 20 μm over 2 m.

Read more ↗
METHOD CASE

Coaxiality and runout by two sections

Example: e = 5 and 15 μm over 400 mm gives about 5″ tilt and 30 μm diameter coaxiality.

Read more ↗
METHOD CASE

Roundness and cylindricity

Example: 3.2 μm in one section with 2 μm centre offset gives cylindricity larger than any single roundness val

Read more ↗
METHOD CASE

Volumetric diagonal test

Example: maxima of 18 and 6 μm across diagonals indicate a directional term to investigate.

Read more ↗
METHOD CASE

Long-term monitoring and trending

Example: baseline 4.2″ with σ = 0.6″; five points above 5.4″ indicate a systematic shift.

Read more ↗
PLAN

Guideway straightness inspection plan

For guideway assembly, adjustment and verification. Agree on the line, span, datum and evaluation method before reconstructing a profile from angular readings.

Read more ↗
PLAN

Surface plate flatness inspection plan

For macroscopic plates, tables and mounting surfaces. Slope integration and direct height measurements require different data inputs.

Read more ↗
PLAN

Machine axis squareness inspection plan

Evaluate the right-angle relation between mean motion-axis directions. Distinguish it from full-surface perpendicularity to a datum.

Read more ↗
PLAN

Aerospace optomechanical assembly reference plan

For geometric checks of payload mounting references, precision fixtures and long guiding structures. This plan is not an airworthiness or structural certification.

Read more ↗
PLAN

Optical assembly alignment and angle inspection plan

For directional adjustment of mirrors, optical platforms and optomechanical mounts. Establish a traceable direction before comparing relative angles.

Read more ↗
PLAN

Optical metrology teaching and laboratory plan

Reproducible exercises for autocollimation, angular conversion, profile reconstruction and error evaluation. Keep example data separate from measured records.

Read more ↗
PLAN

NC machine geometric acceptance (ISO 230-1)

For new-machine acceptance, post-relocation verification or overhaul. Measure each item with agreed lines, travel and evaluation.

Read more ↗
PLAN

Linear axis positioning and repeatability (ISO 230-2)

Positioning, repeatability and reversal error of NC axes, precision stages and linear modules for acceptance, compensation and diagnosis.

Read more ↗
PLAN

Rotary table and indexing head calibration

Full-circle indexing error and repeatability of NC tables, indexing heads and multi-tooth tables for acceptance, compensation and repair verification.

Read more ↗
PLAN

Gantry dual-drive synchronisation and beam geometry

Combined check of synchronisation error, beam deflection and rail parallelism for large machine tools, cutters and additive systems.

Read more ↗
PLAN

Granite plate grid flatness

Flatness of surface plates, machine tables and large bases, including grid design, closure checks and before/after lapping.

Read more ↗
PLAN

Large slewing bearing and flange flatness

Flatness and parallelism of mounting faces on wind, construction and large rotary equipment.

Read more ↗
PLAN

Telescope and multi-axis optical alignment

Alignment of primary and secondary mirrors, sensor boresights and laser transmit/receive paths.

Read more ↗
PLAN

Wafer stage guideway and flatness

Straightness, flatness and thermal stability of wafer, exposure and precision XY stages.

Read more ↗
PLAN

Robot cell installation and calibration

Base level, tool frame and relative pose of external axes or vision systems.

Read more ↗
PLAN

Additive build platform and gantry accuracy

Substrate flatness, powder-bed plane and gantry motion directly affect layer thickness uniformity.

Read more ↗
PLAN

Elevator and track guideway installation

Straightness, parallelism and joint step of elevator, machine and automation guideways for installation crews.

Read more ↗
PLAN

Paper and film roll parallelism

Roll parallelism, elevation and level on paper, film and coating lines to reduce wrinkles and thickness variation.

Read more ↗
PLAN

In-house angular calibration capability

Build internal calibration for autocollimators, electronic levels and angle standards, including equipment, environment and uncertainty budget.

Read more ↗
PLAN

Aerospace tooling and section mating

Datum establishment, mating alignment and contour checks for aircraft sections, wing fixtures and final assembly tooling.

Read more ↗

Every case is marked as a teaching demonstration or method illustration. Data are assumed to explain the calculation and do not represent a customer project or acceptance result.